Evaluation of Proximal Femoral Bone Mineral Density in Cementless Total Hip Arthroplasty: A 3-Arm Prospective Randomized Controlled Trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 38113306.
- Also identified by DOI 10.2106/JBJS.23.00449.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long-term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in 3 morphologically different uncemented femoral stem designs to investigate whether any particular design resulted in better preservation of BMD. A total of 119 patients were randomized to receive a proximally coated collarless dual-taper wedge stem, a proximally coated collarless anatomic stem, or a fully coated collarless triple-taper stem. All surgeries were performed via the posterior approach, with mobilization on the day of surgery. Dual x-ray absorptiometry scans (Lunar iDXA, GE Healthcare) assessed BMD across the 7 Gruen zones preoperatively and at 6 weeks and 2 years postoperatively; if available, the native contralateral femur was also assessed as a control. Patient-reported outcomes of pain, function, and health were also assessed at these follow-ups. Averaged across all stems, BMD increased in zones 1 (2.5%), 2 (17.1%), 3 (13.0%), 5 (10%), and 6 (17.9%) at 2 years. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual-taper wedge and anatomic stems (p = 0.019). The dual-taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7), while the anatomic and triple-taper stems declined in this region; however, the difference did not reach significance (p = 0.059). Averaged across all stems, BMD decreased in the mid-diaphysis region, distal to the stem tip (zone 4). All stems performed similarly at the time of final follow-up with respect to the patient-reported outcomes. This study demonstrated maintenance of femoral BMD after use of 3 different cementless femoral stem designs, with all achieving excellent improvements in patient-reported outcomes. The stems designed to load the proximal metaphyseal region resulted in higher BMD in that region. No significant stress-shielding was observed; however, longer follow-up is required to elucidate the impact of this finding on implant survivorship. Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
Anatomy
- femur
- hip