Portal-site epinephrine injections improve visualisation in arthroscopic rotator cuff repair.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 38218453.
- Also identified by DOI 10.1016/j.jisako.2024.01.007.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to evaluate if portal-site injections of 1:200,000 epinephrine improve intraoperative visualisation in arthroscopic rotator cuff repair. Patients with partial-thickness supraspinatus tears were selected for the study. They were assigned consecutive numbers and were divided into two groups-control group and intervention group. The surgeries were done by a single surgeon. Every odd-numbered patient was injected. Johnson's visibility classification, surgeon 5-point ordinal Likert scale (LS), and other parameters were recorded. A total of 221 participants (58.4 ± 6.1 years) were selected. Intraoperative visibility was better in the intervention group according to Johnson's classification-satisfactory visibility was achieved in 68 of 110 patients (62%, control group) compared to 89 of 111 patients (80%) (p = 0.003). Surgeon LS was superior in the intervention group, with a notable decrease in worsened visibility cases. The operative time did not alter statistically significantly-82.2 ± 14.4 min for the control group, compared to 80.9 ± 10.8 min in the intervention group (p = 0.056). No injection-associated complications were recorded. Portal-site injection of diluted epinephrine solution is safe and improves intraoperative visualisation in arthroscopic rotator cuff repair. This addition does not increase operative time. Level 3, case-control study.
Medical subject headings
- Epinephrine
- Arthroscopy
- Rotator Cuff Injuries
Anatomy
- shoulder