Editorial Commentary: Biocomposite Implant Combined With Local Human Recombinant Parathyroid Hormone Enhances the Histological Quality and Biomechanical Strength of Rotator Cuff Repairs.
editorial · Level V
Where this comes from
- Record sourced from PubMed, PMID 38219093.
- Also identified by DOI 10.1016/j.arthro.2023.11.003.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Rates of rotator cuff repair retear remain unacceptably high and are frequently the source of diminished shoulder function and patient dissatisfaction. Endocrinopathies have been implicated in these processes. Parathyroid hormone (PTH) activates chondrogenesis and angiogenesis at the enthesis and prevents fatty infiltration and atrophy in rotator cuff musculature. These facts have spurred interest in the therapeutic benefits of PTH as a means to enhance tendon healing and strengthen the bone in and around tendon repairs. New research demonstrates that recombinant human PTH delivered locally through a process of coupling it to a bioengineered scaffold "sheath" may be beneficial. The growth factor, encased within polycaprolactone (PCL), is slowly released as the PCL degrades to extend drug delivery time. The augmentation of rotator cuff repairs with this biocomposite material improves short-term structural tissue integrity and promotes the formation of more organized and stronger tendon-to-bone interface in a rabbit model.
Medical subject headings
- Rotator Cuff
- Rotator Cuff Injuries
Anatomy
- shoulder