An interferometric-based tensile tester to resolve damage events within reconstituted multi-filaments collagen bundles.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 38387119.
- Also identified by DOI 10.1016/j.jmbbm.2024.106467.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Understanding how mechanical damage propagates in load-bearing tissues such as skin, tendons and ligaments, is key to developing regenerative medicine solutions for when these tissues fail. For collagenous tissues in particular, damage is typically assessed after mechanical testing using a broad range of microscopy techniques because standard tensile testing systems do not have the time and force sensitivity to resolve mechanical damage events. Here we introduce an interferometric detection scheme to measure the displacement of a cantilever with a resolution of 0.03% of full scale at a sampling rate of 5000 samples/s. The system is validated using collagen fibers engineered to mimic mammalian tendons. The system can detect sudden decrease in force due to slippage between collagen filaments, one to five microns in diameter, within a fiber in air. It can also detect yield events associated with local collagen unfolding or sliding within collagen fibrils within a fiber in liquid. This is opening the road to the sub-failure study of damage propagation within a broad range of hierarchical biomaterials.
Medical subject headings
- Collagen
- Extracellular Matrix