A clinically actionable and explainable real-time risk assessment framework for stroke-associated pneumonia.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 38462273.
- Also identified by DOI 10.1016/j.artmed.2024.102772.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The current medical practice is more responsive rather than proactive, despite the widely recognized value of early disease detection, including improving the quality of care and reducing medical costs. One of the cornerstones of early disease detection is clinically actionable predictions, where predictions are expected to be accurate, stable, real-time and interpretable. As an example, we used stroke-associated pneumonia (SAP), setting up a transformer-encoder-based model that analyzes highly heterogeneous electronic health records in real-time. The model was proven accurate and stable on an independent test set. In addition, it issued at least one warning for 98.6 % of SAP patients, and on average, its alerts were ahead of physician diagnoses by 2.71 days. We applied Integrated Gradient to glean the model's reasoning process. Supplementing the risk scores, the model highlighted critical historical events on patients' trajectories, which were shown to have high clinical relevance.
Medical subject headings
- Pneumonia
- Stroke