Beating Heart Transplant Procedures Using Organs From Donors With Circulatory Death.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 38466306.
- Also identified by DOI 10.1001/jamanetworkopen.2024.1828 and PMC identifier 10928498.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The use of ex vivo normothermic organ perfusion has enabled the use of deceased after circulatory death (DCD) donors for heart transplants. However, compared with conventional brain death donation, DCD heart transplantation performed with ex vivo organ perfusion involves an additional period of warm and cold ischemia, exposing the allograft to multiple bouts of ischemia reperfusion injury and may contribute to the high rates of extracorporeal membrane oxygenation usage after DCD heart transplantation. To assess whether the beating heart method of DCD heart transplantation is safe and whether it has an acceptable rate of extracorporeal membrane oxygenation use postoperatively. This case series includes 10 patients with end-stage heart failure undergoing DCD heart transplantation at a single academic medical center from October 1, 2022, to August 3, 2023. Data were analyzed from October 2022 to August 2023. Using a beating heart method of implantation of the donor allograft. The main outcome was primary graft dysfunction necessitating postoperative initiation of mechanical circulatory support. Survival and initiation of mechanical circulatory support were secondary outcomes. In this case series, 10 consecutive patients underwent DCD heart transplantation via the beating heart method. Ten of 10 recipients were male (100%), the mean (SD) age was 51.2 (13.8) years, and 7 (70%) had idiopathic dilated cardiomyopathy. Ten patients (100%) survived, and 0 patients had initiation of extracorporeal membrane oxygenation postoperatively. No other mechanical circulatory support, including intra-aortic balloon pump, was initiated postoperatively. Graft survival was 100% (10 of 10 patients), and, at the time of publication, no patients have been listed for retransplantation. In this study of 10 patients undergoing heart transplantation, the beating heart implantation method for DCD heart transplantation was safe and may mitigate ischemia reperfusion injury, which may lead to lower rates of primary graft dysfunction necessitating extracorporeal membrane oxygenation. These results are relevant to institutions using DCD donors for heart transplantation.
Medical subject headings
- Primary Graft Dysfunction
- Cardiovascular System
- Heart Transplantation