Highly Porous Acetabular Cup and Augment Constructs in Complex Revision Total Hip Arthroplasty: What Predicts 10-Year Implant Survivorship?
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 38599525.
- Also identified by DOI 10.1016/j.arth.2024.03.071 and PMC identifier 11473099.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Porous tantalum acetabular cup and augment constructs have demonstrated favorable outcomes up to 5 years postsurgery despite severe bone loss during revision total hip arthroplasty (THA). Prior literature lacks long-term studies with substantial case numbers. This study aims to assess long-term clinical and radiographic outcomes 10 years postsurgery in patients undergoing revision THA with porous tantalum acetabular cup-augment constructs and determine factors associated with long-term survivorship. Between 2000 and 2012, 157 revision THAs were performed in cases with major acetabular defects (mainly Paprosky type IIIA and IIIB) utilizing porous tantalum cup-augment constructs. Pelvic discontinuity was noted intraoperatively in 17 hips (11%). Postoperative radiographs were evaluated at regular intervals for implant stability and radiolucent lines. There were 49 patients who had complete radiographic follow-up at 10 years or longer postsurgery. The 10-year survivorship free of revision of the cup-augment construct for aseptic loosening was 93%, free of any acetabular construct revision was 91%, free of any hip rerevision was 77%, and free of any reoperation was 75%. Pelvic discontinuity was associated with increased risk of reoperation (hazard ratio [HR] = 2.8), any hip rerevision (HR = 3.2), any cup-augment construct revision (HR = 11.8), and aseptic construct revision (HR = 10.0). Of unrevised cases with radiographs at 10 years, 4 hips showed radiographic loosening. Mean Harris hip scores improved from 47 preoperatively to 79 at 10 years. Porous tantalum acetabular cup-augment constructs used in revision THA with severe acetabular bone loss provide excellent implant survivorship at 10 years when the acetabulum is intact. Due to lower survivorship of cup-augment constructs in cases of pelvic discontinuity, additional construct fixation or stabilization methods are recommended, when a discontinuity is present. IV.
Medical subject headings
- Humans
- Arthroplasty, Replacement, Hip
- Arthroplasty, Replacement, Hip/instrumentation
- Reoperation
- Reoperation/statistics & numerical data
- Female
- Male
- Acetabulum
- Acetabulum/surgery
- Middle Aged
- Hip Prosthesis
- Aged
- Prosthesis Failure
- Tantalum
- Prosthesis Design
- Adult
- Aged, 80 and over
- Porosity
- Retrospective Studies
- Radiography
- Follow-Up Studies
- Treatment Outcome
Anatomy
- hip
- pelvis