More accurate trabecular bone imaging using UTE MRI at the resonance frequency of fat.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 38631596.
- Also identified by DOI 10.1016/j.bone.2024.117096 and PMC identifier 11357721.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
High-resolution magnetic resonance imaging (HR-MRI) has been increasingly used to assess the trabecular bone structure. High susceptibility at the marrow/bone interface may significantly reduce the marrow's apparent transverse relaxation time (T2*), overestimating trabecular bone thickness. Ultrashort echo time MRI (UTE-MRI) can minimize the signal loss caused by susceptibility-induced T2* shortening. However, UTE-MRI is sensitive to chemical shift artifacts, which manifest as spatial blurring and ringing artifacts partially due to non-Cartesian sampling. In this study, we proposed UTE-MRI at the resonance frequency of fat to minimize marrow-related chemical shift artifacts and the overestimation of trabecular thickness. Cubes of trabecular bone from six donors (75 ± 4 years old) were scanned using a 3 T clinical scanner at the resonance frequencies of fat and water, respectively, using 3D UTE sequences with five TEs (0.032, 1.1, 2.2, 3.3, and 4.4 ms) and a clinical 3D gradient echo (GRE) sequence at 0.2 × 0.2 × 0.4 mm<sup>3</sup> voxel size. Trabecular bone thickness was measured in 30 regions of interest (ROIs) per sample. MRI results were compared with thicknesses obtained from micro-computed tomography (μCT) at 50 μm<sup>3</sup> voxel size. Linear regression models were used to calculate the coefficient of determination between MRI- and μCT-based trabecular thickness. All MRI-based trabecular thicknesses showed significant correlations with μCT measurements. The correlations were higher (examined with paired Student's t-test, P < 0.01) for 3D UTE images performed at the fat frequency (R<sup>2</sup> = 0.59-0.74, P < 0.01) than those at the water frequency (R<sup>2</sup> = 0.18-0.52, P < 0.01) and clinical GRE images (R<sup>2</sup> = 0.39-0.47, P < 0.01). Significantly reduced correlations were observed with longer TEs. This study highlighted the feasibility of UTE-MRI at the fat frequency for a more accurate assessment of trabecular bone thickness.
Medical subject headings
- Magnetic Resonance Imaging
- Cancellous Bone