LADRC-based grid-connected control strategy for single-phase LCL-type inverters.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 38748696.
- Also identified by DOI 10.1371/journal.pone.0303591 and PMC identifier 11095700.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To ensure that grid-connected currents are of high quality, it is crucial to optimize the dynamic performance of grid-connected inverters and their control. This study suggests using a combination of reduced-order linear active disturbance rejection control (LADRC) and a Proportional-Integral (PI) controller. By applying this control strategy to a single-phase photovoltaic grid-connected system, the system's ability to suppress grid harmonics is significantly improved. The validity and effectiveness of this control approach have been confirmed through simulations and experiments. The results show that the LADRC-based control system is robust and capable of rejecting disturbances, resulting in a significant reduction in the Total Harmonic Distortion (THD) of grid-connected currents. Comparative analysis with traditional control methods demonstrates the superior performance of the proposed approach.
Medical subject headings
- Algorithms