The effect of time-delayed contrast-enhanced scanning in determining the gross tumor target volume of large-volume brain metastases.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 38768715.
- Also identified by DOI 10.1016/j.radonc.2024.110330.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess the variation of large-volume brain metastases (BMs) boundaries and shapes using enhanced magnetic resonance (MR) scanning with different delay times and to provide a basis for determining the gross tumor target volume (GTV) for radiotherapy of BMs. We prospectively enrolled 155 patients initially diagnosed with BMs (561 lesions > 1 cm). Contrast-enhanced (CE) T1-weighted imaging scans were performed 1, 3, 5, 10, 18, and 20 min after gadolinium-based contrast agent injection and GTVs were determined as GTV<sub>-1min</sub>, GTV<sub>-3min</sub>, GTV<sub>-5min</sub>, GTV<sub>-10min</sub>, GTV<sub>-18min</sub>, and GTV<sub>-20min,</sub> respectively, which were subsequently fused in different phases. Fusion of the six GTVs was defined as GTV<sub>-total</sub>, which was set as the reference GTV. The volume, shape, and signal intensity of the GTVs and brain white matter (BWM) were compared at different delay times. GTV<sub>-3min</sub>, GTV<sub>-5min</sub>, GTV<sub>-10min</sub>, GTV<sub>-18min</sub>, and GTV<sub>-20min</sub> volumes increased by 2.2 %, 3.8 %, 6.5 %, 9.5 %, and 10.6 %, respectively (P < 0.05) compared with GTV<sub>-1min</sub>. Compared with GTV<sub>-total</sub>, GTV<sub>-1min</sub>, GTV<sub>-3min</sub>, GTV<sub>-5min</sub>, GTV<sub>-10min</sub>, GTV<sub>-18min</sub>, and GTV<sub>-20min</sub> volumes reduced by 25.4 %, 22.1 %, 18.7 %, 15.0 %, 11.2 %, and 10.3 %, respectively (P < 0.05). Compared with GTV<sub>-total</sub>, 29 (51.8 %) fused GTVs had a volume reduction rate < 5 %, 45 (80.4 %) had a Dice similarity coefficient > 0.95, and all contained GTV<sub>-10min</sub>, GTV<sub>-18min</sub> or GTV<sub>-20min</sub>. The signal intensity ratio between the GTV and BWM peaked at 5 min (0.351 ± 0.24). Enhanced MR scans with different delay times show significant differences in the boundaries and shapes of large-volume BMs, and time-delayed multi-phase CE scanning should be used in GTV determination, with time phases ≥ 10 min being mandatory.
Medical subject headings
- Brain Neoplasms
- Contrast Media
- Magnetic Resonance Imaging