Clinical results and computed tomography analysis of intuitive shoulder arthroplasty (ISA) stemless at a minimum follow-up of 2 years.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 38851524.
- Also identified by DOI 10.1016/j.jse.2024.04.012.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The utilization of stemless anatomic total shoulder arthroplasty is on the rise. Epiphyseal fixation leads to radiological bone remodeling, which has been reported to exceed 40% in certain studies series. The aim of this study was to present the clinical and radiological outcomes of a stemless implant with asymmetric central epiphyseal fixation at an average follow-up of 31 months. This retrospective multicenter study examined prospective data of patients undergoing total anatomic arthroplasty with intuitive shoulder arthroplasty Stemless implant and followed up at least 2 years. Clinical assessment included preoperative and final follow-up measurements of active range of motion, Constant score, and Subjective Shoulder Value. Anatomical epiphyseal reconstruction and bone remodeling at the 2-year follow-up were assessed by standardized computed tomography scanner (CT scan). Statistical analysis employed unpaired Student's t-test or chi-squared test depending on the variable type, conducted using EasyMedStat software (version 3.22; www.easymedstat.com). Fifty patients (mean age 68 years, 62% females) were enrolled, with an average follow-up of 31 months (24-44). Primary osteoarthritis (68%) with type A glenoid (78%) was the prevailing indication. The mean Constant score and Subjective Shoulder Value improved significantly from 38 ± 11 to 76 ± 11 (P < .001) and from 31% ± 16 to 88% ± 15 (P < .001) respectively at the last follow-up. Forward elevation, external rotation, and internal rotation range of motion increased by 39° ± 42, 28° ± 21 and 3,2 ± 2,5 points respectively, surpassing the Minimally Clinically Important Difference after total shoulder arthroplasty. No revisions were necessary. CT scans identified 30% osteolysis in the posterior-medial calcar region, devoid of clinical repercussions. No risk factors were associated with bone osteolysis. At an average follow-up of 31 months, intuitive shoulder arthroplasty Stemless implant provided favorable clinical results. CT analysis revealed osteolysis-like remodeling in the posterior-medial zone of the calcar (30%), without decline in clinical outcomes and revisions. Long-term follow-up studies are mandated to evaluate whether osteolysis is associated with negative consequences.
Medical subject headings
- Arthroplasty, Replacement, Shoulder
- Tomography, X-Ray Computed
- Shoulder Prosthesis
- Shoulder Joint
- Osteoarthritis
Anatomy
- shoulder