Double-row staple technology versus triple-row staple technology for colorectal surgery: A systematic review and meta-analysis.
meta_analysis · Level I
Where this comes from
- Record sourced from PubMed, PMID 38876899.
- Also identified by DOI 10.1016/j.surg.2024.04.039.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Some observational data have suggested that anastomotic leak may be reduced with triple-row staple technology compared to double-row staple technology. We aimed to investigate this further by performing a systematic review comparing double- and triple-row staple technology for colorectal anastomoses. This systematic review was reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. MEDLINE, Embase, and Cochrane Central Register of Controlled Trials databases were searched up to November 2023. Articles were eligible for inclusion if they were comparing double-row staple and triple-row staple technology for left-sided colo-colic, colorectal, or coloanal anastomosis. The main outcomes included anastomotic leak, anastomotic hemorrhage, 30-day mortality, and reoperation. Meta-analyses with inverse variance random effects were performed. Certainty of evidence was assessed with Grading of Recommendations, Assessment, Development, and Evaluations. After reviewing 340 relevant citations, 6 retrospective cohort studies met inclusion. Overall, 19,372 patients (mean age: 60.2 years, 52.7% female sex) had anastomoses with double-row staple technology, and 2,298 patients (mean age: 61.3 years, 50.3% female sex) with triple-row staple technology. Most operations were anterior resections (double-row: 55.3%; triple-row: 43.6%). Across all included studies, the risk of anastomotic leak was reduced with triple-row staple technology (6.3% vs 7.5%, risk ratio 0.54, 95% confidence interval 0.31-0.94, P = .03, I<sup>2</sup>=75%). There were no significant differences in anastomotic hemorrhage (risk ratio 0.47, 95% confidence interval 0.15-1.49, P = .20, I<sup>2</sup> = 57%), 30-day mortality (risk ratio 0.66, 95% confidence interval 0.17-2.55, P = .55, I<sup>2</sup> = 0%), or reoperation (risk ratio 1.05, 95% confidence interval 0.42-2.64, P = .91, I<sup>2</sup> = 56%). Triple-row staple technology may reduce the risk of anastomotic leak in left-sided colorectal anastomoses.
Medical subject headings
- Anastomotic Leak
- Surgical Stapling
- Anastomosis, Surgical