Diagnostic test accuracy of externally validated convolutional neural network (CNN) artificial intelligence (AI) models for emergency head CT scans - A systematic review.
systematic_review · Level I
Where this comes from
- Record sourced from PubMed, PMID 38901270.
- Also identified by DOI 10.1016/j.ijmedinf.2024.105523.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The surge in emergency head CT imaging and artificial intelligence (AI) advancements, especially deep learning (DL) and convolutional neural networks (CNN), have accelerated the development of computer-aided diagnosis (CADx) for emergency imaging. External validation assesses model generalizability, providing preliminary evidence of clinical potential. This study systematically reviews externally validated CNN-CADx models for emergency head CT scans, critically appraises diagnostic test accuracy (DTA), and assesses adherence to reporting guidelines. Studies comparing CNN-CADx model performance to reference standard were eligible. The review was registered in PROSPERO (CRD42023411641) and conducted on Medline, Embase, EBM-Reviews and Web of Science following PRISMA-DTA guideline. DTA reporting were systematically extracted and appraised using standardised checklists (STARD, CHARMS, CLAIM, TRIPOD, PROBAST, QUADAS-2). Six of 5636 identified studies were eligible. The common target condition was intracranial haemorrhage (ICH), and intended workflow roles auxiliary to experts. Due to methodological and clinical between-study variation, meta-analysis was inappropriate. The scan-level sensitivity exceeded 90 % in 5/6 studies, while specificities ranged from 58,0-97,7 %. The SROC 95 % predictive region was markedly broader than the confidence region, ranging above 50 % sensitivity and 20 % specificity. All studies had unclear or high risk of bias and concern for applicability (QUADAS-2, PROBAST), and reporting adherence was below 50 % in 20 of 32 TRIPOD items. 0.01 % of identified studies met the eligibility criteria. The evidence on the DTA of CNN-CADx models for emergency head CT scans remains limited in the scope of this review, as the reviewed studies were scarce, inapt for meta-analysis and undermined by inadequate methodological conduct and reporting. Properly conducted, external validation remains preliminary for evaluating the clinical potential of AI-CADx models, but prospective and pragmatic clinical validation in comparative trials remains most crucial. In conclusion, future AI-CADx research processes should be methodologically standardized and reported in a clinically meaningful way to avoid research waste.
Medical subject headings
- Tomography, X-Ray Computed
- Neural Networks, Computer