Establishing Updated Safety Standards for Independent <sup>99</sup><sup>m</sup>Tc-MAA SPECT/CT Treatment Planning in Radioembolization.

Kim, Taehyung Peter; Gandhi, Ripal T; Tolakanahalli, Ranjini; Herrera, Robert; Chuong, Michael D; Gutierrez, Alonso N; Alvarez, Diane · Int J Radiat Oncol Biol Phys · 2024

retrospective_cohort · Level III

Where this comes from

Abstract

Significant improvements within radioembolization imaging and dosimetry permit the development of an accurate and personalized pretreatment plan using technetium 99m-labeled macroaggregated albumin (<sup>99</sup><sup>m</sup>Tc-MAA) and single-photon emission computed tomography (SPECT) combined with anatomical CT (SPECT/CT). Despite these potential advantages, the clinical transition to pretreatment protocols with SPECT/CT is hindered by their unknown safety constraints. This study aimed to address this issue by establishing novel dose limits for <sup>99</sup><sup>m</sup>Tc-MAA SPECT/CT to enable quantitative pretreatment planning. Stratification criteria to determine images most viable for dosimetry analysis were created from a cohort of 85 patients. SPECT/CT, cone beam CT, and activity calculations derived from the local deposition method were used to create an accurate pretreatment protocol. Planar and SPECT/CT images were compared using linear regression and modified Bland-Altman analyses to convert accepted planar dose limits to SPECT/CT. To validate these new dose limits, activity calculations based on SPECT/CT were compared with those calculated with the body surface area and planar methods for three treatment plans. A total of 38 of 85 patients were deemed viable for dosimetry analysis. SPECT yielded greater lung shunt fractions (LSFs) than planar imaging when LSFs were <4.89%, whereas SPECT yielded lower LSFs than planar imaging when LSFs were >4.89%. Planar to SPECT/CT dose conversions were 0.76×, 0.70×, and 0.55× for the whole liver, normal liver, and lungs, respectively. Patients with SPECT LSFs ≤4.89% were safely treated with the direct application of planar lung dose limits. Activity calculations with the newly established SPECT/CT dose limits were greater than those of the body surface area method by a median range of 33.1% to 61.9% and were lower than planar-based activity calculations by a median range of 12.5% to 13.7% for the whole liver and by 29.4% to 32.2% for the normal liver. This study demonstrated a safe method for translating dose limits from <sup>99</sup><sup>m</sup>Tc-MAA planar imaging to SPECT/CT. A robust pretreatment protocol was further developed guided by the current knowledge in the field. Established SPECT/CT dose limits safely treated 97.5% of patients and permitted the application of independent pretreatment planning with <sup>99</sup><sup>m</sup>Tc-MAA SPECT/CT.

Medical subject headings