Measurement of iron absorption and iron gains from birth to 6 months in breastfed and formula-fed infants using iron isotope dilution.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 38985881.
- Also identified by DOI 10.1126/sciadv.ado4262 and PMC identifier 11235178.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Little is known about iron kinetics in early infancy. We administered stable iron isotopes to pregnant women and used maternal-fetal iron transfer to enrich newborn body iron. Dilution of enriched body iron by dietary iron with natural isotopic composition was used to assess iron kinetics from birth to 6 months. In breastfed (BF, n = 8), formula-fed (FF, n = 7), or mixed feeding (MF, n = 8) infants, median (interquartile range) iron intake was 0.27, 11.19 (10.46-15.55), and 4.13 (2.33-6.95) mg/day; iron absorbed was 0.128 (0.095-0.180), 0.457 (0.374-0.617), and 0.391 (0.283-0.473) mg/day (BF versus FF, P < 0.01); and total iron gains were 0.027 (-0.002-0.055), 0.349 (0.260-0.498), and 0.276 (0.175-0.368) mg/day (BF versus FF, P < 0.001; BF versus MF, P < 0.05). Isotope dilution can quantify long-term iron absorption and describe the trajectory of iron depletion during early infancy.
Medical subject headings
- Breast Feeding
- Iron Isotopes
- Iron
- Infant Formula