Awake Robotic Minimally Invasive Transforaminal Lumbar Interbody Fusion Under Spinal Anesthesia: A Prospective Study with 1-Year Follow-up.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 38986938.
- Also identified by DOI 10.1016/j.wneu.2024.07.044.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We describe our protocol and outcomes of awake robotic minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) under spinal anesthesia. We conducted a prospective study of 10 consecutive patients undergoing awake robotic single-level MIS-TLIF with the Mazor X robot. We prospectively collected patient-reported outcomes (back and leg pain visual analog scale and Oswestry Disability Index) preoperatively at 1-month and 1-year follow-ups and assessed fusion and screw placement accuracy with a 1-year computed tomography (CT) scan. Median age was 61 years (interquartile range [IQR] = 57.7-66). Median body mass index was 27 kg/m<sup>2</sup>. No intraoperative complications were reported. Most (9/10) patients were discharged home, and 50% discharged on the day of surgery. Median length of stay was 16.5 hours (IQR = 5-35.5). Median follow-up was 12.5 months (IQR = 12-13.5), with 9 patients having at least 12-month follow-up, with CT scans documenting good screw placement (Gertzbein-Robbins grade A) and solid bony fusion. Median preoperative back pain visual analog scale score was 7.8 (IQR = 6.9-8) versus 1.5 (IQR = 0-3.2) at 1-month post operation, P < 0.01, and 0 (IQR = 0-1) at 1-year follow-up, P < 0.01; median preoperative leg pain 8 (IQR = 7.4-8) versus 0 (IQR = 0-1.2) at 1-month post operation, P < 0.01, and 0 (IQR = 0-2) at 1-year follow-up, P < 0.01; median preoperative Oswestry Disability Index 47.5 (IQR = 27.8-57.5) versus 4 (IQR = 0-16) at 1-month postoperation, P < 0.01, and 0 (IQR = 0-7) at 1-year follow-up, P < 0.01. Median preoperative disk height of the index level was 8 mm (IQR = 2.4-9.5) versus 11.4 mm (IQR = 9.2-11.2) postoperatively,P < 0.01. Median preoperative lordosis of the index level was 5 degrees (IQR = 3.4-8.5) versus 10.1 degrees (7.3-12.2) postoperatively, P < 0.01. Our study showed significant improvement in patient-reported outcomes at 1-month and 1-year follow-ups after awake robotic MIS-TLIF, as well as solid bony fusion on CT scans.
Medical subject headings
- Spinal Fusion
- Robotic Surgical Procedures
- Lumbar Vertebrae
- Minimally Invasive Surgical Procedures
- Anesthesia, Spinal