Novel method of iliac accessory rods for rod fracture prevention in adult deformity surgery: a case series of 82 patients with outcomes and complications.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 39059456.
- Also identified by DOI 10.3171/2024.5.SPINE24208.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Primary rod fracture after surgery for adult spinal deformity (ASD) is a leading cause of revision, with recent prospective multicenter fracture rates reported at 11%-14% by 2 years. Consequently, the addition of supplemental rods has been explored to reduce fractures. Here the authors describe their experience with a novel iliac accessory rod technique in which each accessory rod anchors to an independent iliac bolt caudally via lateral connector, and attaches to the primary rod rostrally via side-to-side connector. This retrospective, single-center case series included patients who underwent thoracolumbar/lumbar fusion for ASD between March 2019 and August 2023. Data on baseline demographics, radiographic parameters, surgical characteristics, complications, rod fracture, and revision rates were collected. Paired, 2-tailed t-tests were used to compare pre- and postoperative radiographic outcomes. Rod fracture rates were compared to prior investigations via chi-square goodness of fit testing. The technique for iliac accessory rod placement is described. The study consisted of 82 patients (mean age 66 years, 51% female, 26% with prior fusion) with a median follow-up of 2 years (IQR 28-104 weeks). A total of 50 patients (61%) had ≥ 2-year follow-up. Each surgery involved an average of 4 posterior column osteotomies and 8 segments. Iliac accessory rods were cobalt chromium and were placed bilaterally in 87% of constructs. Postoperative alignment improved significantly in the following parameters: maximum coronal Cobb angle, fractional curve, sagittal vertical axis, lumbar lordosis, thoracic kyphosis, and pelvic incidence to lumbar lordosis mismatch (p < 0.001 for all comparisons). Of 50 patients with ≥ 2-year follow-up, rod fracture occurred in 1 (2.0%), which was incidentally found and required no intervention. The present rod fracture rate was significantly lower than the authors' historically reported institutional rate of 21% for traditional dual-rod constructs, and the 11%-14% reported in recent prospective multicenter studies that used traditional and supplemental rod constructs (p < 0.05 for all comparisons). Reoperation occurred in 12 patients (14.6%); 7 (8.5%) for proximal junctional kyphosis and 5 (6.1%) for wound complication. Here the authors describe their experience with a novel iliac accessory rod technique to prevent rod fracture in patients undergoing surgery for ASD. The 2-year rod fracture rate (2.0%) in this study is significantly lower than the authors' historical dual-rod fracture rate, and other prospective multicenter investigations. Future studies with longer follow-up are needed to determine the durability of this technique.
Medical subject headings
- Spinal Fusion
- Ilium
- Lumbar Vertebrae
- Postoperative Complications
- Thoracic Vertebrae
- Spinal Curvatures
Anatomy
- lumbar spine
- thoracic spine
- pelvis