High Rates of Early Septic Failure, but Low Rates of Aseptic Loosening After Revision Total Knee Arthroplasty With Contemporary Rotating-Hinge Prostheses.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 39147074.
- Also identified by DOI 10.1016/j.arth.2024.08.013.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to determine implant survivorship and functional outcomes for revision total knee arthroplasty (rTKA) with contemporary rotating-hinge knee implants. A retrospective review identified 115 rTKAs using contemporary rotating-hinge implants from 2014 to 2018 for the treatment of instability (34, 30%), reimplantation after periprosthetic joint infection (PJI) (33, 29%), aseptic loosening (25, 22%), arthrofibrosis (14, 12%), periprosthetic fracture (4, 3%), osteolysis (4, 3%), and femoral component fracture (1, 1%). There were 70 women (61%), and the mean age was 67 years (range, 27 to 94). The mean follow-up was 3 years (range, 2 to 6). Kaplan-Meier analysis and Cox proportional hazard models estimated survivorship. The re-revision rate was 20% (23 of 115) at an average of 18 months postoperatively. Re-revision indications included PJI (n = 14), aseptic loosening (n = 4), arthrofibrosis (n = 2), instability/malalignment (n = 1), femoral stem fracture (n = 1), and hinge mechanism disruption (n = 1). At 2 and 5 years, survivorship free from all-cause re-revision was 86 and 64%, and survivorship free from re-revision for aseptic loosening was 100 and 87%, respectively. Use of a rotating-hinge implant in reimplantation after PJI was a risk factor for subsequent re-revision (hazard ratio = 2.4, P = 0.046). On a radiographic review of unrevised rotating-hinges, there were major radiolucent lines around 2 femoral and 5 tibial components. The mean Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement increased from 43 preoperatively to 60 at 1 year (P < 0.001). In patients treated with a rotating-hinge implant for rTKA, there were relatively poor 2-year (86%) and 5-year (64%) survivorship free from all-cause re-revision, most commonly due to PJI. Midterm survivorship free from re-revision for aseptic loosening was modest (87%). There should be a goal to mitigate complications in complex rTKAs with rotating-hinge implants, namely PJI.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Reoperation
- Knee Prosthesis
- Prosthesis Failure
- Prosthesis-Related Infections
Anatomy
- knee