Effects of carbon versus plastic ankle foot orthoses on gait outcomes and energy cost in patients with chronic stroke.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 39175453.
- Also identified by DOI 10.2340/jrm.v56.35213 and PMC identifier 11358842.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
To compare the walking performances of hemiplegic subjects with chronic stroke under 3 conditions: with a new standard carbon fibre ankle foot orthosis (C-AFO), with a personal custom-made plastic AFO (P-AFO), and without any orthosis (No-AFO). Randomized, controlled crossover design. Fifteen chronic patients with stroke (3 women and 12 men, 59 [10] years, 13 [15] years since injury). Patients performed 3 randomized sessions (with C-AFO, P-AFO, no-AFO), consisting of a 6-min walk test (6MWT) with VO2 measurement and a clinical gait analysis. Energy cost (Cw), walking speed, spatio-temporal, kinetic, and kinematic variables were measured. No significant differences were found between the C-AFO and P-AFO conditions. Distance and walking speed in the 6MWT increased by 12% and 10% (p < 0.001) and stride width decreased by -8.7% and -13% (p < 0.0001) with P-AFO and C-AFO compared with the No-AFO condition. Cw decreased by 15% (p < 0.002), stride length increased by 10% (p < 0.01), step length on affected leg increased by 8% (p < 0.01), step length on contralateral leg by 13% (p < 0.01), and swing time on the contralateral leg increased by 6% (p < 0.01) with both AFO compared with the No-AFO condition. The use of an off-the-shelf composite AFO (after a short habituation period) in patients with chronic stroke immediately improved energy cost and gait outcomes to the same extent as their usual custom-made AFO.
Medical subject headings
- Foot Orthoses
- Stroke Rehabilitation
- Cross-Over Studies
- Energy Metabolism
- Stroke
- Gait