Automated detection of large vessel occlusion using deep learning: a pivotal multicenter study and reader performance study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 39304193.
- Also identified by DOI 10.1136/jnis-2024-022254 and PMC identifier 12573350.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the stand-alone efficacy and improvements in diagnostic accuracy of early-career physicians of the artificial intelligence (AI) software to detect large vessel occlusion (LVO) in CT angiography (CTA). This multicenter study included 595 ischemic stroke patients from January 2021 to September 2023. Standard references and LVO locations were determined by consensus among three experts. The efficacy of the AI software was benchmarked against standard references, and its impact on the diagnostic accuracy of four residents involved in stroke care was assessed. The area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity of the software and readers with versus without AI assistance were calculated. Among the 595 patients (mean age 68.5±13.4 years, 56% male), 275 (46.2%) had LVO. The median time interval from the last known well time to the CTA was 46.0 hours (IQR 11.8-64.4). For LVO detection, the software demonstrated a sensitivity of 0.858 (95% CI 0.811 to 0.897) and a specificity of 0.969 (95% CI 0.943 to 0.985). In subjects whose symptom onset to imaging was within 24 hours (n=195), the software exhibited an AUROC of 0.973 (95% CI 0.939 to 0.991), a sensitivity of 0.890 (95% CI 0.817 to 0.936), and a specificity of 0.965 (95% CI 0.902 to 0.991). Reading with AI assistance improved sensitivity by 4.0% (2.17 to 5.84%) and AUROC by 0.024 (0.015 to 0.033) (all P<0.001) compared with readings without AI assistance. The AI software demonstrated a high detection rate for LVO. In addition, the software improved diagnostic accuracy of early-career physicians in detecting LVO, streamlining stroke workflow in the emergency room.
Medical subject headings
- Deep Learning
- Computed Tomography Angiography
- Ischemic Stroke