Detectability of Hypoattenuating Liver Lesions with Deep Learning CT Reconstruction: A Phantom and Patient Study.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 39377679.
- Also identified by DOI 10.1148/radiol.232749 and PMC identifier 11535864.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Background CT deep learning image reconstruction (DLIR) improves image quality by reducing noise compared with adaptive statistical iterative reconstruction-V (ASIR-V). However, objective assessment of low-contrast lesion detectability is lacking. Purpose To investigate low-contrast detectability of hypoattenuating liver lesions on CT scans reconstructed with DLIR compared with CT scans reconstructed with ASIR-V in a patient and a phantom study. Materials and Methods This single-center retrospective study included patients undergoing portal venous phase abdominal CT between February and May 2021 and a low-contrast-resolution phantom scanned with the same protocol. Four reconstructions (ASIR-V at 40% strength [ASIR-V 40] and DLIR at three strengths) were generated. Five radiologists qualitatively assessed the images using the five-point Likert scale for image quality, lesion diagnostic confidence, conspicuity, and small lesion (≤1 cm) visibility. Up to two key lesions per patient, confirmed at histopathologic testing or at prior or follow-up imaging studies, were included. Lesion-to-background contrast-to-noise ratio was calculated. Interreader variability was analyzed. Intergroup qualitative and quantitative metrics were compared between DLIR and ASIR-V 40 using proportional odds logistic regression models. Results Eighty-six liver lesions (mean size, 15 mm ± 9.5 [SD]) in 50 patients (median age, 62 years [IQR, 57-73 years]; 27 [54%] female patients) were included. Differences were not detected for various qualitative low-contrast detectability metrics between ASIR-V 40 and DLIR (<i>P</i> > .05). Quantitatively, medium-strength DLIR and high-strength DLIR yielded higher lesion-to-background contrast-to-noise ratios than ASIR-V 40 (medium-strength DLIR vs ASIR-V 40: odds ratio [OR], 1.96 [95% CI: 1.65, 2.33]; high-strength DLIR vs ASIR-V 40: OR, 5.36 [95% CI: 3.68, 7.82]; <i>P</i> < .001). Low-contrast lesion attenuation was reduced by 2.8-3.6 HU with DLIR. Interreader agreement was moderate to very good for the qualitative metrics. Subgroup analysis based on lesion size of larger than 1 cm and 1 cm or smaller yielded similar results (<i>P</i> > .05). Qualitatively, phantom study results were similar to those in patients (<i>P</i> > .05). Conclusion The detectability of low-contrast liver lesions was similar on CT scans reconstructed with low-, medium-, and high-strength DLIR and ASIR-V 40 in both patient and phantom studies. Lesion-to-background contrast-to-noise ratios were higher for DLIR medium- and high-strength reconstructions compared with ASIR-V 40. © RSNA, 2024 <i>Supplemental material is available for this article.</i>
Medical subject headings
- Deep Learning
- Tomography, X-Ray Computed
- Phantoms, Imaging
- Liver Neoplasms
- Radiographic Image Interpretation, Computer-Assisted