Fluid balance neutralization secured by hemodynamic monitoring versus protocolized standard of care in patients with acute circulatory failure requiring continuous renal replacement therapy: results of the GO NEUTRAL randomized controlled trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 39417870.
- Also identified by DOI 10.1007/s00134-024-07676-1 and PMC identifier 11588767.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Net ultrafiltration (UF<sub>NET</sub>) during continuous renal replacement therapy (CRRT) can control fluid balance (FB), but is usually 0 ml·h<sup>-1</sup> in patients with vasopressors due to the risk of hemodynamic instability associated with CRRT (HIRRT). We evaluated a UF<sub>NET</sub> strategy adjusted by functional hemodynamics to control the FB of patients with vasopressors, compared to the standard of care. In this randomized, controlled, open-label, parallel-group, multicenter, proof-of-concept trial, adults receiving vasopressors, CRRT since ≤ 24 h and cardiac output monitoring were randomized (ratio 1:1) to receive during 72 h a UF<sub>NET</sub> ≥ 100 ml·h<sup>-1</sup>, adjusted using a functional hemodynamic protocol (intervention), or a UF<sub>NET</sub> ≤ 25 ml·h<sup>-1</sup> (control). The primary outcome was the cumulative FB at 72 h and was analyzed in patients alive at 72 h and in whom monitoring and CRRT were continuously provided (modified intention-to-treat population [mITT]). Secondary outcomes were analyzed in the intention-to-treat (ITT) population. Between June 2021 and April 2023, 55 patients (age 69 [interquartile range, IQR: 62; 74], 35% female, Sequential Organ Failure Assessment (SOFA) 13 [11; 15]) were randomized (25 interventions, 30 controls). In the mITT population, (21 interventions, 24 controls), the 72 h FB was -2650 [-4574; -309] ml in the intervention arm, and 1841 [821; 5327] ml in controls (difference: 4942 [95% confidence interval: 2736-6902] ml, P < 0.01). Hemodynamics, oxygenation and the number of HIRRT at 72 h, and day-90 mortality did not statistically differ between arms. In patients with vasopressors, a UF<sub>NET</sub> fluid removal strategy secured by a hemodynamic protocol allowed active fluid balance control, compared to the standard of care.
Medical subject headings
- Continuous Renal Replacement Therapy
- Water-Electrolyte Balance
- Hemodynamic Monitoring