Biomechanical Analysis of a Modified Triangular Osteosynthesis Technique for Treatment of Spinopelvic Dissociation.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 39431813.
- Also identified by DOI 10.1097/BOT.0000000000002882.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to evaluate the biomechanical stability of a modified triangular osteosynthesis construct with S1 pedicle screws compared with other described lumbopelvic fixation constructs in a U-type sacral fracture model. U-type sacral fractures were created in validated fourth-generation spinopelvic models. Four different constructs were cyclically loaded with displacement measured in all planes: (1) bilateral L5 pedicle screws with rods attached to iliac bolts, (2) bilateral L5 and S1 pedicle screws with rods attached to iliac bolts, (3) bilateral L5 pedicle screws with rods attached to iliac bolts with a transsacral-transiliac screw, and (4) bilateral L5 and S1 pedicle screws with rods attached to iliac bolts with a transsacral-transiliac screw. The bilateral L5 and S1 pedicle screws with rods attached to iliac bolts with a transsacral-transiliac screw construct had significantly decreased horizontal, vertical, and angular displacement compared with all other constructs. From a biomechanical perspective, a modified triangular osteosynthesis construct with S1 pedicle screws improves stability in fixation of U-type sacral fractures.
Medical subject headings
- Fracture Fixation, Internal
- Sacrum
- Spinal Fractures
Anatomy
- sacrum-coccyx
- pelvis