Safety and performance of the ultrathin sirolimus-eluting coronary stent in an all-comer patient population: the S-FLEX UK-II registry.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 39438097.
- Also identified by DOI 10.1136/bmjopen-2024-084028 and PMC identifier 11499841.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We evaluated the clinical safety and performance of the ultrathin strut biodegradable polymer-coated Supraflex Cruz (Sahajanand Medical TechnologiesLtd., Surat, India) sirolimus-eluting stent (SES) in an all-comer patient population requiring coronary stent implantation. The study was a prospective, observational, multicentre, single-arm registry. The study was conducted at 19 NHS Hospitals across the UK, from March 2020 to September 2021. A total of 1904 patients with symptomatic coronary artery disease (age ≥18 years) who underwent percutaneous coronary intervention with at least one Supraflex Cruz SES were enrolled. The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI) and clinically indicated target lesion revascularisation (CI-TLR), at 12 months. Safety endpoints were stent thrombosis, all-cause death and any MI. Prespecified subgroups analysis included patients with diabetes mellitus, bifurcation lesion, type B2/C lesion defined as per ACC/AHA (American College of Cardiology/American Heart Association) lesion classification and long coronary lesions (>20 mm). A total of 2973 Supraflex Cruz SES were implanted in 1835 patients (mean age: 65.20±11.03 years). Of these, 404 patients had diabetes mellitus (491 lesions), 271 had bifurcation lesions (293 lesions), 1541 had type B2/C lesions (1832 lesions) and 985 had long coronary lesions (>20 mm, 1139 lesions). Among the overall population, device success was achieved in 98.2% of lesions. TLF occurred in 12 (0.7%) patients (0.3% cardiac death, 0.2% TV-MI, 0.2% CI-TLR) at 30 days and in 43 (2.3%) patients (0.8% cardiac death, 0.8% TV-MI, 0.8% CI-TLR) at 12 months follow-up. The rate of definite stent thrombosis was 0.3% in the overall population at 12 months. The incidence of TLF and stent thrombosis was 6.2% and 1% in the diabetic, 1.8% and none in bifurcation lesion, 2.5% and 0.3% in type B2/C lesion, and 2.7% and 0.3% in long coronary lesions (>20 mm) subgroups, respectively. at 12 months follow-up. The S-FLEX UK-II registry confirms the clinical safety and performance of the ultrathin Supraflex Cruz SES in an all-comer population with complex coronary artery disease, demonstrating low rates of TLF and stent thrombosis. ISRCTN39751665 (https://doi.org/10.1186/ISRCTN39751665).
Medical subject headings
- Coronary Artery Disease
- Drug-Eluting Stents
- Prosthesis Design
- Sirolimus