Patch-walking, a coordinated multi-pipette patch clamp for efficiently finding synaptic connections.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 39556439.
- Also identified by DOI 10.7554/eLife.97399 and PMC identifier 11573346.
- Licence recorded as CC0.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Significant technical challenges exist when measuring synaptic connections between neurons in living brain tissue. The patch clamping technique, when used to probe for synaptic connections, is manually laborious and time-consuming. To improve its efficiency, we pursued another approach: instead of retracting all patch clamping electrodes after each recording attempt, we cleaned just one of them and reused it to obtain another recording while maintaining the others. With one new patch clamp recording attempt, many new connections can be probed. By placing one pipette in front of the others in this way, one can 'walk' across the mouse brain slice, termed 'patch-walking.' We performed 136 patch clamp attempts for two pipettes, achieving 71 successful whole cell recordings (52.2%). Of these, we probed 29 pairs (i.e. 58 bidirectional probed connections) averaging 91 μm intersomatic distance, finding three connections. Patch-walking yields 80-92% more probed connections, for experiments with 10-100 cells than the traditional synaptic connection searching method.
Medical subject headings
- Patch-Clamp Techniques
- Synapses
- Neurons