Minimum two-year follow-up of a reverse total shoulder arthroplasty using a wedged baseplate.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 39582720.
- Also identified by DOI 10.1177/17585732241293396 and PMC identifier 11579998.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Avoiding inclination of the glenoid baseplate in reverse shoulder arthroplasty often requires considerable glenoid reaming. It is proposed that the use of a metal wedged baseplate in all patients can achieve neutral inclination with reduced glenoid reaming. A prospective clinical single-centre study with minimum two-year follow-up was carried out. Glenoid deformity was classified on CT and surgery planned using BluePrint<sup>TM</sup>. The Tornier Perform<sup>®</sup> Reversed Wedged Augmented Glenoid was used in all cases. Clinical outcome scores and radiographs were assessed. Seventy-three patients, mean age 76.6 years. Twenty-eight demonstrated no glenoid deformity and 19 demonstrated marked retroversion. Seventy completed two-year follow-up. Mean pain scores fell from 6 to 0.7. All Patient Reported Outcome Meaures (PROMS) were significantly improved. Active elevation increased by 62° and external rotation by 28.7° (<i>p</i> < 0.001). In patients with no glenoid wear (E0/A1), correction of inferior inclination was achievable with a 15° full-wedge baseplate in all cases, reducing the reaming depth by 4.4 mm (<i>p</i> < 0.001). In patients with severe glenoid wear, a 35° half wedge baseplate was often necessary to correct the deformity. The most common complications were stress reactions/fractures. A metal wedged baseplate can achieve neutral inclination in all patients, minimising bone reaming and preserving lateralisation with good two-year outcomes. IV (case series with no comparison group).
Anatomy
- shoulder