Minimum two-year follow-up of a reverse total shoulder arthroplasty using a wedged baseplate.

Parker, Simon J M; Bell, Simon N; Wiemer, Féoline; Coghlan, Jennifer A; Clitherow, Harry D; Rayment, Helen M · Shoulder Elbow · 2024

prospective_cohort · Level II

Where this comes from

Abstract

Avoiding inclination of the glenoid baseplate in reverse shoulder arthroplasty often requires considerable glenoid reaming. It is proposed that the use of a metal wedged baseplate in all patients can achieve neutral inclination with reduced glenoid reaming. A prospective clinical single-centre study with minimum two-year follow-up was carried out. Glenoid deformity was classified on CT and surgery planned using BluePrint<sup>TM</sup>. The Tornier Perform<sup>®</sup> Reversed Wedged Augmented Glenoid was used in all cases. Clinical outcome scores and radiographs were assessed. Seventy-three patients, mean age 76.6 years. Twenty-eight demonstrated no glenoid deformity and 19 demonstrated marked retroversion. Seventy completed two-year follow-up. Mean pain scores fell from 6 to 0.7. All Patient Reported Outcome Meaures (PROMS) were significantly improved. Active elevation increased by 62° and external rotation by 28.7° (<i>p</i> < 0.001). In patients with no glenoid wear (E0/A1), correction of inferior inclination was achievable with a 15° full-wedge baseplate in all cases, reducing the reaming depth by 4.4 mm (<i>p</i> < 0.001). In patients with severe glenoid wear, a 35° half wedge baseplate was often necessary to correct the deformity. The most common complications were stress reactions/fractures. A metal wedged baseplate can achieve neutral inclination in all patients, minimising bone reaming and preserving lateralisation with good two-year outcomes. IV (case series with no comparison group).

Anatomy