SPECT-CT may aid in determining which side of a revision stemmed implant problematic total knee replacement is loose when planning revision surgery.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 39591899.
- Also identified by DOI 10.1016/j.knee.2024.10.016.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate SPECT-CT in the diagnosis of single component aseptic loosening in patients with a problematic cemented stemmed TKR (Total Knee Replacement). SPECT-CT was performed where aseptic loosening was suspected but was not clear on plain radiography. Demographics, suspected diagnosis and intention to revise were collected prospectively before and after SPECT-CT. 30 patients were investigated. 43% (95% CI: 0.5-0.9) had clear evidence of loosening on SPECT-CT. In 23% (95% CI: 0.1-0.4) intention to perform revision surgery following SPECT-CT changed (7/30) (p = 0.0004, standard error = 42.1, z = 3.5). Intentions to perform revision surgery according to the radiologist's overall summary were: Normal SPECT-CT - 0% (95% CI: 0.0-0.8) intention to revise (0/2). Possibly abnormal SPECT-CT - 13% (95% CI: 0.0-0.4) intention to revise (2/15). Definitely abnormal SPECT-CT - 77% (95% CI: 0.5-0.9) intention to revise (10/13). We report that SPECT-CT had a test sensitivity of 90.9% (95% CI: 0.6-1.0), a specificity of 100% (95% CI: 0.9-1.0), a positive predictive value of 100% and a negative predictive value of 97.7%. In 70% (95% CI: 0.3-0.9) of cases where revision surgery was performed for aseptic loosening SPECT-CT provided information that guided pre-operative planning with regards single component or both component revision surgery (7/10). When positive SPECT-CT was useful in determining single component revision. A normal SPECT-CT may have a negative predictive value; however, overall half of our series had a possibly abnormal or equivocal investigation.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Reoperation
- Prosthesis Failure
- Knee Prosthesis
Anatomy
- knee