Influence of dosimetry accuracy on the correlation with treatment outcome in a preliminary PSMA radiopharmaceutical therapy study.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 39704811.
- Also identified by DOI 10.1007/s00259-024-07010-3 and PMC identifier 11928392.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Despite the potential of dosimetry in optimizing personalized radiopharmaceutical therapy (RPT), its limited clinical implementation impedes the development of simplified protocols for routine adoption. However, simplifications may introduce errors in dosimetry, prompting questions about their impact on clinical practice. In this retrospective study, we analyzed data from 21 patients diagnosed with metastatic castration-resistant prostate cancer (mCRPC) who underwent multiple cycles of <sup>177</sup>Lu-PSMA-617 RPT treatment. Cumulative dosimetry of all the treatment cycles was calculated using both the standard multi-time point dosimetry (MTPD) method and the single time-point dosimetry (STPD, Hänscheid approximation) method for the same cohort. Their correlations with treatment outcome (PSA decline rate and overall survival, OS) and complication risk (anaemia grade) were investigated. The Fisher's Z-Transformed test was performed to statistically evaluate the difference between the correlations. STPD showed a non-significant difference in correlation with PSA decline rate, despite a mean percentage error (MPE) of up to 36.44% in tumor dosimetry compared to MTPD (MTPD: rho = -0.39, p < 0.001; STPD: rho = -0.46, p < 0.001; Z = 0.58, p = 0.56). Both STPD<sub>total</sub> and MTPD<sub>total</sub> demonstrated a significant impact on OS (STPD<sub>total</sub>: Hazard Ratio = 1.05, p < 0.05, log-transformed MTPD<sub>total</sub>: Hazard Ratio = 3.41, p < 0.05, log-transformed STPD<sub>total</sub>: Hazard Ratio = 8.06, p < 0.05). Additionally, despite a MPE of up to -40.26% in bone marrow dosimetry, STPD showed a non-significant difference in correlation with anemia grade (MTPD: rho = 0.35, p < 0.001; STPD: rho = 0.40, p < 0.001; Z = -0.39, p = 0.70). The preliminary findings from a small cohort indicate that the reduced accuracy of a clinically simplified protocol may not diminish the clinical therapy outcome predictive value of dosimetry. Future thorough systematic investigations may be needed to determine the clinically acceptable level of accuracy for dosimetry.
Medical subject headings
- Radiopharmaceuticals
- Prostatic Neoplasms, Castration-Resistant
- Dipeptides
- Heterocyclic Compounds, 1-Ring