Comparison of Plasma p-tau217 and [<sup>18</sup>F]FDG-PET for Identifying Alzheimer Disease in People With Early-Onset or Atypical Dementia.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 39715476.
- Also identified by DOI 10.1212/WNL.0000000000210211 and PMC identifier 11666273.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare the diagnostic performance of an immunoassay for plasma concentrations of phosphorylated tau (p-tau) 217 with visual assessments of fluorine-18 fluorodeoxyglucose [<sup>18</sup>F]FDG-PET in individuals who meet appropriate use criteria for Alzheimer dementia (AD) biomarker assessments. We performed a retrospective analysis of individuals with early-onset (age <65 years at onset) and/or atypical dementia (features other than memory at onset), who were evaluated at a tertiary care memory clinic. All participants underwent measurements of CSF biomarkers (Aβ42, p-tau181, and total tau levels), as well as [<sup>18</sup>F]FDG-PET scans, amyloid-PET scans, and plasma p-tau217 quantifications. To determine whether the [<sup>18</sup>F]FDG-PET images were compatible with AD, images were visually rated by 2 nuclear medicine experts. Using a contingency analysis, we evaluated the accuracy of [<sup>18</sup>F]FDG-PET scan interpretation and plasma p-tau217 for an AD biomarker profile in CSF and for amyloid-PET positivity. A total of 81 individuals with early onset and/or atypical dementia were included in this study (mean age = 65 years; 48/81 female (59%). Both [<sup>18</sup>F]FDG-PET and plasma p-tau217 showed high levels of agreement with reference standard AD biomarkers ([<sup>18</sup>F]FDG-PET area under the curve [AUC]: 71%; plasma p-tau217 AUC: 81%). Although both biomarkers had similar specificity for AD [<sup>18</sup>F]FDG-PET: 70%, CI: 0.56-0.81; plasma p-tau217: 70%, CI: 0.56-0.81), plasma p-tau217 had higher sensitivity for AD (plasma p-tau217: 97%, CI: 0.85-0.99 vs [<sup>18</sup>F]FDG-PET: 73%, CI: 0.57-0.85) (<i>p</i> = 0.01). Overall accuracy was also higher for plasma p-tau217 (AUC = 84%, CI: 0.75-0.93 vs 72%, CI: 0.60-0.83 of [<sup>18</sup>F]FDG-PET) (<i>p</i> = 0.02). The same pattern of results was observed when using amyloid-PET as the reference standard. Our study provides evidence that plasma p-tau217 has strong discriminative accuracy for AD among patients with early-onset and/or atypical dementia assessed in specialized settings. Future work should replicate these findings in secondary care settings.
Medical subject headings
- Alzheimer Disease
- Fluorodeoxyglucose F18
- Positron-Emission Tomography
- tau Proteins
- Biomarkers