Supervised multi-frame dual-channel denoising enables long-term single-molecule FRET under extremely low photon budget.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 39746928.
- Also identified by DOI 10.1038/s41467-024-54652-w and PMC identifier 11697068.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Camera-based single-molecule techniques have emerged as crucial tools in revolutionizing the understanding of biochemical and cellular processes due to their ability to capture dynamic processes with high precision, high-throughput capabilities, and methodological maturity. However, the stringent requirement in photon number per frame and the limited number of photons emitted by each fluorophore before photobleaching pose a challenge to achieving both high temporal resolution and long observation times. In this work, we introduce MUFFLE, a supervised deep-learning denoising method that enables single-molecule FRET with up to 10-fold reduction in photon requirement per frame. In practice, MUFFLE extends the total number of observation frames by a factor of 10 or more, greatly relieving the trade-off between temporal resolution and observation length and allowing for long-term measurements even without the need for oxygen scavenging systems and triplet state quenchers.
Medical subject headings
- Fluorescence Resonance Energy Transfer
- Photons
- Single Molecule Imaging