Magnetic resonance angiography in diagnostic long-term follow-up of primary patency of the MOTIV drug-eluting bioresorbable vascular scaffold in the region below the knee: 5 years of experience.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 39854598.
- Also identified by DOI 10.1371/journal.pone.0313696 and PMC identifier 11761161.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Treatment of peripheral artery disease (PAD) in the region below the knee (BTK) is dissatisfying as failure of treated target lesions (TLF) is frequent and diagnostic imaging is often challenging. In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions. Patency of the deBVS in the BTK-region was assessed retrospectively using contrast enhanced MR-A of the lower limbs in patients with PAD of Lafontaine-grades II-IV (n = 19). Clinically driven MR-A censoring was triggered by an assumed target lesion failure (CD-TLF), which served to compute the probability of PP during the observation period of 5 years. Compatibility of this particular deBVS with MRI was additionally proven via in-vitro experiments. The scaffold was found to be fully compatible with MRI. The normalised intra-luminal signal measured in MR-A increased significantly after successful deBVS-placement. The retrospective 5-years PP-probability was 0.87 (CI95%: [0.71,1.0]) with 2 stent-occlusions observed after 90 days. No major adverse events occurred. Assessment of PAD in the BTK-region after placement of the Tyrocore®-deBVS using MRA is feasible. The promising high PP-probability after 5-years and the persistent full interpretability of treated target lesions by MR-A after stent-placement encourage further prospective assessment of this deBVS in treatment of PAD in the BTK-region.
Medical subject headings
- Magnetic Resonance Angiography
- Drug-Eluting Stents
- Peripheral Arterial Disease
- Absorbable Implants
- Vascular Patency
- Tissue Scaffolds