Repeated OGTT Versus Continuous Glucose Monitoring for Predicting Development of Stage 3 Type 1 Diabetes: A Longitudinal Analysis.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 39903487.
- Also identified by DOI 10.2337/dc24-2376 and PMC identifier 11932814.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Evidence for using continuous glucose monitoring (CGM) as an alternative to oral glucose tolerance tests (OGTTs) in presymptomatic type 1 diabetes is primarily cross-sectional. We used longitudinal data to compare the diagnostic performance of repeated CGM, HbA1c, and OGTT metrics to predict progression to stage 3 type 1 diabetes. Thirty-four multiple autoantibody-positive first-degree relatives (FDRs) (BMI SD score [SDS] <2) were followed in a multicenter study with semiannual 5-day CGM recordings, HbA1c, and OGTT for a median of 3.5 (interquartile range [IQR] 2.0-7.5) years. Longitudinal patterns were compared based on progression status. Prediction of rapid (<3 years) and overall progression to stage 3 was assessed using receiver operating characteristic (ROC) areas under the curve (AUCs), Kaplan-Meier method, baseline Cox proportional hazards models (concordance), and extended Cox proportional hazards models with time-varying covariates in multiple record data (n = 197 OGTTs and concomitant CGM recordings), adjusted for intraindividual correlations (corrected Akaike information criterion [AICc]). After a median of 40 (IQR 20-91) months, 17 of 34 FDRs (baseline median age 16.6 years) developed stage 3 type 1 diabetes. CGM metrics increased close to onset, paralleling changes in OGTT, both with substantial intra- and interindividual variability. Cross-sectionally, the best OGTT and CGM metrics similarly predicted rapid (ROC AUC = 0.86-0.92) and overall progression (concordance = 0.73-0.78). In longitudinal models, OGTT-derived AUC glucose (AICc = 71) outperformed the best CGM metric (AICc = 75) and HbA1c (AICc = 80) (all P < 0.001). HbA1c complemented repeated CGM metrics (AICc = 68), though OGTT-based multivariable models remained superior (AICc = 59). In longitudinal models, repeated CGM and HbA1c were nearly as effective as OGTT in predicting stage 3 type 1 diabetes and may be more convenient for long-term clinical monitoring.
Medical subject headings
- Diabetes Mellitus, Type 1
- Blood Glucose
- Blood Glucose Self-Monitoring