Total-Body Parametric Imaging Using Relative Patlak Plot.

Li, Siqi; Abdelhafez, Yasser G; Nardo, Lorenzo; Cherry, Simon R; Badawi, Ramsey D; Wang, Guobao · J Nucl Med · 2025

Where this comes from

Abstract

The standard Patlak plot, a simple yet efficient model, is widely used to describe irreversible tracer kinetics for dynamic PET imaging. Its widespread application to whole-body parametric imaging remains constrained because of the need for a full-time-course input function (e.g., 1 h). In this paper, we demonstrate the relative Patlak (RP) plot, which eliminates the need for the early-time input function, for total-body parametric imaging and its application to 20-min clinical scans acquired in list mode. <b>Methods:</b> We conducted a theoretic analysis to indicate that the RP intercept <i>b</i>' is equivalent to a ratio of the SUV relative to the plasma concentration, whereas the RP slope <i>K<sub>i</sub></i> ' is equal to the standard Patlak <i>K<sub>i</sub></i> (net influx rate) multiplied by a global scaling factor for each subject. One challenge in applying RP to a short scan duration (e.g., 20 min) is the resulting high noise in the parametric images. We applied a self-supervised deep-kernel method for noise reduction. Using the standard Patlak plot as the reference, the RP method was evaluated for lesion quantification, lesion-to-background contrast, and myocardial visualization in total-body parametric imaging in 22 human subjects (12 healthy subjects and 10 cancer patients) who underwent a 1-h dynamic <sup>18</sup>F-FDG scan. The RP method was also applied to the dynamic data reconstructed from a clinical standard 20-min list-mode scan either at 1 or 2 h after injection for 2 cancer patients. <b>Results:</b> We demonstrated that it is feasible to obtain high-quality parametric images from 20-min scans using RP parametric imaging with a self-supervised deep-kernel noise-reduction strategy. The RP slope <i>K<sub>i</sub></i> ' was highly correlated with the standard Patlak <i>K<sub>i</sub></i> in lesions and major organs, demonstrating its quantitative potential across subjects. Compared with conventional SUVs, the <i>K<sub>i</sub></i> ' images significantly improved lesion contrast and enabled visualization of the myocardium for potential cardiac assessment. The application of the RP parametric imaging to the 2 clinical scans also showed similar benefits. <b>Conclusion:</b> Using total-body PET with the RP approach, it is feasible to generate parametric images using data from a 20-min clinical list-mode scan.

Medical subject headings