Assessing the Impact of Advanced Cooling Technology in Firefighting Gear During Live Burn Scenario.

Yu, Zhaochong; Altman, Lorenna; Fang, Qichen; Bellacov, Ryan; Davis, Rosie; Davis, Kermit; Kubley, Ashley; Kim, Myoung Ok et al. · J Occup Environ Med · 2025

other

Where this comes from

Abstract

A firefighter wears a standard safety coat, its model unchanged for many years, when tackling a fire. We designed a new cooling system coat with carbon nanotube-based fabric and pouches inside the coat for coolants and fans. The coats, one standard and the other still evolving, are compared on several metrics including core body temperature and thermal comfort. An experimental protocol was designed involving a live burn facility under the paradigm of noninferiority study with firefighters trying both coats. The metrics are measured at several phases of the protocol. Multivariate t test is used to compare the performance of the coats. The new coat is not inferior to the standard coat. The new coat in its final form, which is yet to be tested fully, is a plausible replacement for the standard coat.

Medical subject headings