Tumor Dose-Response Relationship of [<sup>131</sup>I]MIBG Therapy in Patients with Neural Crest Tumors by Means of [<sup>124</sup>I]MIBG PET.

Moraitis, Alexandros; Prochnow, Andre; Poeppel, Thorsten Dirk; Schmitz, Jochen; Laschinsky, Christina; Herrmann, Ken; Bockisch, Andreas; Fragoso Costa, Pedro et al. · J Nucl Med · 2025

Where this comes from

Abstract

[<sup>131</sup>I]Metaiodobenzylguanidine (MIBG) therapy in patients with neural crest tumors has demonstrated sustained control of catecholamine-associated hypertension and corresponding partial response. Details on how neural crest tumors respond to an absorbed dose delivered by [<sup>131</sup>I]MIBG-targeted therapies is insufficiently known. The primary aim of this retrospective study was to assess the tumor dose-response relationship by means of quantitative analysis of [<sup>124</sup>I]MIBG PET data. <b>Methods:</b> The tumor dose-response relationship was studied in patients with advanced malignant pheochromocytoma, neuroblastoma, or paraganglioma receiving [<sup>131</sup>I]MIBG treatment, as well as pretherapeutic and follow-up [<sup>124</sup>I]MIBG-based dosimetry. [<sup>124</sup>I]MIBG PET imaging was performed around 4, 24, 48, and 120 h after injection. Lesion uptake was projected to [<sup>131</sup>I]MIBG for every time point, and respective time-integrated activity coefficients (TIACs) for [<sup>131</sup>I]MIBG were calculated and used for tumor-absorbed dose estimation. Functional response was denoted for decrease of maximal lesion uptake or TIAC by at least 30% in the follow-up examination. In a consecutive analysis, the predictive value of a single tumor-uptake assessment from PET imaging at 24 h after administration was investigated with respect to receiving the derived target dose. <b>Results:</b> In total, 46 lesions from 9 patients were available for dose-response analysis. The mean ± SD tumor-absorbed dose coefficient was 13.4 ± 15.4 Gy/GBq (median, 7.2 Gy/GBq; range, 1.1-64.7 Gy/GBq). A high correlation (-0.60, <i>P</i> < 0.001) was found between uptake decrease and tumor dose. In addition, a very high correlation (0.91, <i>P</i> < 0.001) was found between uptake and TIAC decrease. The estimated targeted tumor dose was 200 Gy, that is, the dose at which the response rate exceeded the 90% threshold. A single 24-h uptake assessment showed predictive value with respect to receiving the target dose. <b>Conclusion:</b> This study demonstrated a clear correlation between tumor-absorbed dose and functional response in [<sup>131</sup>I]MIBG therapy and proposes a target dose for response at the tumor level.