Long-Term Outcomes of Third-Generation Ceramic-on-Ceramic Bearings in Cementless Primary Total Hip Arthroplasty: A 25-Year Survival Analysis.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 40107579.
- Also identified by DOI 10.1016/j.arth.2025.03.029.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The demand for total hip arthroplasty (THA) in younger patients, particularly those under 65 years, has increased markedly in recent years. Ceramic-on-ceramic (CoC) bearings offer promising benefits, including reduced wear and osteolysis, with excellent short- to mid-term survival. However, long-term data on their performance in younger populations remain limited. This study aimed to investigate: (1) overall implant survival, (2) complications and reasons for revision, and (3) patient-reported outcomes at long-term follow-up after primary THA with third-generation CoC bearings. A retrospective analysis was performed on 231 patients (294 hips) who underwent cementless THA with third-generation CoC bearings between May 1999 and September 2004. The mean age at surgery was 50 years (range, 17 to 76). Clinical and radiographic outcomes were assessed at a minimum follow-up of 10 years, and the mean follow-up was 17 years (range, 10 to 25). Overall, 87 patients (108 hips, 38%) were lost to follow-up, leaving a total of 145 patients (186 hips) for further analysis. Kaplan-Meier survival analysis was used to estimate implant survival, with implant revision for any reason defined as a primary end point. Complications, reasons for revision, and patient-reported outcomes (Merle d'Aubigné-Postel score) were also evaluated. Kaplan-Meier analysis demonstrated an implant survival rate of 93% at 25 years. At long-term follow-up, 12 hips (6.5%) required revision for either bearing failure (six hips), acetabular component failure (four hips), or femoral component failure (two hips). There were six cases of hip squeaking (3.2%) reported, none requiring revision. Functional outcomes improved significantly, with mean Merle d'Aubigné-Postel scores rising from 10.7 preoperatively to 17.6 at the final follow-up. Radiographic evaluations showed no cases of osteolysis or loosening. Third-generation CoC bearings in cementless THA offer excellent long-term survival, low complication rates, and good to excellent functional outcomes, highlighting their durability and performance over a 25-year period.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Ceramics
- Prosthesis Design
Anatomy
- hip