Diagnostic performance of NIRADS on F-18 FDG PET/CT in the post-treatment assessment of head and neck malignancies - a systematic review and meta-analysis.
systematic_review · Level I
Where this comes from
- Record sourced from PubMed, PMID 40137977.
- Also identified by DOI 10.1007/s00259-025-07230-1.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This review aimed to evaluate the diagnostic performance of Neck Imaging Reporting and Data System (NIRADS) categories using 2-deoxy 2-(Fluorine-18) fluoro D-glucose positron emission tomography integrated with computed tomography (F-18 FDG PET/CT) to diagnose recurrence or treatment failure in the post-treatment assessment of head and neck squamous cell carcinoma (HNSCC). A systematic search of the indexed medical literature was conducted till 7 November 2024 using PubMed, Scopus, Cochrane Library and Google Scholar to include studies reporting post-treatment recurrence rates on F-18-FDG PET/CT as per the NIRADS criteria. Studies were qualitatively assessed for risk of bias using the QUADAS-2 tool. We categorized patients with 'NI-RADS≤2' as low risk of recurrence and 'NI-RADS ≥3' as high risk of recurrence. Diagnostic performance of NI-RADS was evaluated through weighted-pooling of standard metrics of diagnostic accuracy, diagnostic Odd's ratio (DOR) and summary receiver operator characteristic (SROC) curve analysis. Out of 1632 records identified, 8 studies with 7 datasets were included, with over 1200 patients and over 1300 F-18 FDG PET/CT scans. All studies were retrospective, with presence of a risk for bias, publication bias and data heterogeneity. The time between treatment and F-18 FDG PET/CT assessment was 8-17 weeks. For combined sites (primary, nodal or distant sites), the ability of 'NIRADS ≥3' over 'NIRADS ≤2' to detect a recurrence was acceptable with a pooled sensitivity, specificity, positive and negative likelihood ratios of 0.68 (95% Confidence Interval, CI 0.63-0.73), 0.90 (95% CI, 0.88-0.92), 6.01 (95% CI, 2.9- 12.6) and 0.47 (95% CI, 0.31- 0.71) respectively, with a DOR of 14.13 (95% CI, 9.78-20.42) and an area under the curve, AUC of 0.859 (Standard Error, SE -0.018) on SROC analysis CONCLUSION: In F-18 FDG PET/CT done on post-treatment HNSCC patients, the diagnostic performance of NIRADS ≥3 categories over NIRADS ≤ 2 categories in detecting treatment failure or recurrence at combined primary, nodal or distant sites was acceptable, with a low certainty of evidence. The NIRADS categories, especially NIRADS ≥3 and NIRADS ≤2 categories should be routinely reported in post-treatment F-18 FDG PET/CT scans in HNSCC patients. (No funding received; PROSPERO No. CRD42022376017).
Medical subject headings
- Positron Emission Tomography Computed Tomography
- Fluorodeoxyglucose F18
- Head and Neck Neoplasms