Comparison of Thiel-fixed and fresh-frozen temporal bon biomechanics with dynamic synchrotron-based X-ray imaging.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 40222160.
- Also identified by DOI 10.1016/j.clinbiomech.2025.106522.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The Thiel embalming method offers lifelike tissue preservation, yet its suitability for biomechanical studies remains debated. Here, we investigated two human temporal bones, one Thiel-fixed and one fresh-frozen, using dynamic synchrotron-based X-ray imaging under acoustic stimulation. Both specimens exhibited a linear response at the umbo, but the Thiel-fixed specimen displayed discontinuity after the incudo-malleolar joint, suggesting ossicular chain stiffening. Our findings align well with previous studies indicating potential tissue degradation induced by Thiel-embalming. These observations question the use of Thiel-fixed human specimens for biomechanical measurements on the middle ear, especially using dynamic synchrotron-based X-ray imaging. They emphasize the need for further assessment of the impact of Thiel-embalming methods on tissue mechanics.
Medical subject headings
- Synchrotrons
- Temporal Bone
- Embalming