Biomechanical comparison of plate, intramedullary screw, and headless compression screw fixation in Danis-Weber type B lateral malleolar fractures.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 40264226.
- Also identified by DOI 10.1186/s13018-025-05783-3 and PMC identifier 12016078.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Weber type B transsyndesmotic fractures are the most common type of lateral malleolar fractures, a common ankle fracture type. Although several surgical techniques are available for fixation, no clinical consensus exists regarding the optimal fixation method. This study evaluated the biomechanical differences in fixation stability among one-third tubular plates, 3.5-mm intramedullary screws, and 4.5-mm intramedullary headless compression screws for Weber type B lateral malleolar fractures using an in Vitro mechanical analysis. In total, 24 artificial fibula bone specimens were used. The specimens were subjected to Weber type B lateral malleolar fractures using a saw blade and randomly divided into three groups treated with different fixation methods, with eight specimens per group: (1) One-third tubular plate, (2) 3.5-mm intramedullary screw, and (3) 4.5-mm intramedullary headless compression screw. The specimens were subjected to bending and torsional mechanical testing using a materials testing system. The bending test was evaluated using 10-mm displacement force (Newtons) and bending stiffness (Newtons/millimeter) as the assessment parameters. For the torsional test, 20° rotation torque (Newtons/millimeter) and torsional stiffness (Newton∙millimeters/degree) were used as evaluation parameters. The experimental results were analyzed using the Kruskal-Wallis test. When significant differences were found, post hoc pairwise comparisons were conducted using the Dunn-Bonferroni approach. In the bending test, no statistical differences were observed between the three fixation methods, whether evaluated by 10-mm displacement force or bending stiffness. Nevertheless, for the 20° rotation torque assessment in the torsional test, both the one-third tubular plate (1360.31 ± 221.56 N·mm, median ± interquartile range) and the 4.5-mm intramedullary headless compression screw (1420.41 ± 281.95 N·mm) exhibited similar resistance, considerably outperforming the 3.5-mm intramedullary screw (605.80 ± 165.11 N·mm) in fracture fixation strength. In the torsional stiffness assessment, both the one-third tubular plate (67.67 ± 15.39 N·mm, median ± interquartile range) and the 4.5-mm intramedullary headless compression screw (62.44 ± 17.36 N·mm) exhibited equivalent resistance and were substantially superior to the 3.5-mm intramedullary screw (25.90 ± 5.1 N·mm) in their ability to fix fractures. The 4.5-mm intramedullary headless compression screw provides strong mechanical stability and a lower risk of soft tissue complications in clinical practice. Therefore, this headless compression screw can be recommended as a fixation option for Weber type B lateral malleolar fractures.
Medical subject headings
- Bone Screws
- Ankle Fractures
- Bone Plates
- Fracture Fixation, Intramedullary
- Fracture Fixation, Internal
Anatomy
- ankle