Five-year clinical outcomes of metal-backed, hybrid, and polyethylene glenoid components in total shoulder arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 40405637.
- Also identified by DOI 10.5397/cise.2025.00136 and PMC identifier 12151647.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The glenoid components in total shoulder arthroplasty (TSA) are numerous and have both advantages and disadvantages. This study aimed to compare 5-year functional outcomes, patient-reported outcomes, and conversion rates between patients who underwent TSA using metal-backed glenoid (MBG), hybrid, and all-polyethylene glenoid components. The patients who were eligible for this study were retrospectively identified using electronic health records. The subjects underwent TSA performed by a fellowship-trained attending physician from November 2017 to December 2018 at a single institution. The inclusion criteria from 5-year follow-up data were adult-age patients (≥18 years old) who underwent TSA using MBG, hybrid, or all-polyethylene glenoid components. A total of 77 patients was included: 44 patients with all-polyethylene glenoid components, 17 with hybrid glenoid components, and 16 with MBG components. The mean patient age was 66.9 years, with the all-polyethylene patients being significantly younger (P<0.001). The all-polyethylene glenoid patients experienced a significantly longer operative time at 120 minutes (P=0.005) compared to those with other components. At the 5-year follow-up, no significant difference was shown in American Shoulder and Elbow Surgeons (ASES) and visual analog scale scores. However, a trend was evident in which the all-polyethylene patients had lower ASES scores (all polyethylene 87.0 vs. hybrid 100.0 vs. 97.0 MBG, P=0.086). The hybrid components tended to require revision more often at 12% vs. 6.8% of polyethylene glenoid vs. 0% of MBGs (P=0.310). No dislocation was reported, and only two complications occurred, both in the all-polyethylene group (P=0.387). At 5-year follow-up, patient-reported outcomes were similar when utilizing MBG, all-polyethylene, and hybrid glenoid components. Given the similar outcomes, MBGs and hybrid glenoid components could be considered favorable or preferred for potential surgical ease in a revision setting with conversion to reverse TSA. Level of evidence: III.
Anatomy
- shoulder