Revisiting Euclidean alignment for transfer learning in EEG-based brain-computer interfaces.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 40425023.
- Also identified by DOI 10.1088/1741-2552/addd49.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Due to large intra-subject and inter-subject variabilities of electroencephalogram (EEG) signals, EEG-based brain-computer interfaces (BCIs) usually need subject-specific calibration to tailor the decoding algorithm for each new subject, which is time-consuming and user-unfriendly, hindering their real-world applications. Transfer learning (TL) has been extensively used to expedite the calibration, by making use of EEG data from other subjects/sessions. An important consideration in TL for EEG-based BCIs is to reduce the data distribution discrepancies among different subjects/sessions, to avoid negative transfer. Euclidean alignment (EA) was proposed in 2020 to address this challenge. Numerous experiments from 13 different BCI paradigms demonstrated its effectiveness and efficiency. This paper revisits EA, explaining its procedure and correct usage, introducing its applications and extensions, and pointing out potential new research directions. It should be very helpful to BCI researchers, especially those who are working on EEG signal decoding.
Medical subject headings
- Brain-Computer Interfaces
- Electroencephalography
- Machine Learning
- Transfer, Psychology