The Effect of A1 Segment Dominance on Angular Morphology of the Anterior Communicating Artery Bifurcation in Healthy and Aneurysmal Patients.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 40782914.
- Also identified by DOI 10.1016/j.wneu.2025.124359.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The anterior communicating artery (ACOM) bifurcation, a common site for aneurysm formation, carries high risk of aneurysm rupture. Due to its anastomotic nature, it exhibits complex hemodynamic and morphological profiles. Previously, ACOM angles were evaluated without accounting for unique characteristics. We evaluate ACOM angular morphology bilaterally, based on A1 trunk dominance (size and angiographic presentation), in aneurysmal and healthy patients. Bilateral catheter 3D rotational angiographic studies were available from 67 patients with ACOM aneurysms and 54 nonaneurysmal controls (242 samples total). A1 segments were classified as dominant, codominant, or nondominant based on relative diameter. Angle between ACOM and A2 segment (AcomA2) and angle between A1 and A2 segments (A1A2) angles were measured on 2D cut planes. Matched-pair analysis was performed on aneurysmal and nonaneurysmal patients with dominant/nondominant segment labels. Aneurysms occurred on dominant (70.1%) or codominant A1 segments. A1A2 angles were significantly wider in aneurysmal bifurcations (74.1 ± 21.75°) than contralateral (53.88 ± 21.59°, P < 0.001) and nonaneurysmal controls (42.44 ± 14.43°, P < 0.001), with a threshold of 59.2° (area under the curve = 0.88). AcomA2 angle could not be evaluated in 90 volumes (37.2%) due to poor angiographic visibility of the ACOM. In unilateral and matched-pair analysis, A1A2 was significantly wider in dominant control bifurcations than nondominant sides (45.85 ± 9.83° vs. 34.47 ± 12.21°, P = 0.003). ACOM angular morphology is strongly determined by A1 dominance, independent of aneurysm presence. Unlike the AcomA2 angle, A1A2 was measurable in all samples and reliably captured bifurcation angulation. ACOM bifurcations, unlike other bifurcations, require bilateral morphological and hemodynamic evaluation of the full ACOM complex. These findings inform future evaluation and modeling of cerebral vascular architecture.
Medical subject headings
- Intracranial Aneurysm
- Anterior Cerebral Artery