Development and validation of a multimodal automatic interictal epileptiform discharge detection model: a prospective multi-center study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 40817241.
- Also identified by DOI 10.1186/s12916-025-04316-3 and PMC identifier 12357389.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Visual identification of interictal epileptiform discharge (IED) is expert-biased and time-consuming. Accurate automated IED detection models can facilitate epilepsy diagnosis. This study aims to develop a multimodal IED detection model (vEpiNetV2) and conduct a multi-center validation. We constructed a large training dataset to train vEpiNetV2, which comprises 26,706 IEDs and 194,797 non-IED 4-s video-EEG epochs from 530 patients at Peking Union Medical College Hospital (PUMCH). The automated IED detection model was constructed using deep learning based on video and electroencephalogram (EEG) features. We proposed a bad channel removal model and patient detection method to improve the robustness of vEpiNetV2 for multi-center validation. Performance is verified in a prospective multi-center test dataset, with area under the precision-recall curve (AUPRC) and area under the curve (AUC) as metrics. To fairly evaluate the model performance, we constructed a large test dataset containing 149 patients, 377 h video-EEG data, and 9232 IEDs from PUMCH, Children's Hospital Affiliated to Shandong University (SDQLCH) and Beijing Tiantan Hospital (BJTTH). Amplitude discrepancies are observed across centers and could be classified by a classifier. vEpiNetV2 demonstrated favorable accuracy for the IED detection, achieving AUPRC/AUC values of 0.76/0.98 (PUMCH), 0.78/0.96 (SDQLCH), and 0.76/0.98 (BJTTH), with false positive rates of 0.16-0.31 per minute at 80% sensitivity. Incorporating video features improves precision by 9%, 7%, and 5% at three centers, respectively. At 95% sensitivity, video features eliminated 24% false positives in the whole test dataset. While bad channels decreased model precision, video features compensate for this deficiency. Accurate patient detection is essential; otherwise, incorrect patient detection can negatively impact overall performance. The multimodal IED detection model, which integrates video and EEG features, demonstrated high precision and robustness. The large multi-center validation confirmed its potential for real-world clinical application and the value of video features in IED analysis.
Medical subject headings
- Electroencephalography
- Epilepsy