What happens to the elbow 15 years after a radial head prosthesis? A clinical and imaging long-term follow-up study.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 40825472.
- Also identified by DOI 10.1016/j.jse.2025.06.026.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Radial head arthroplasty (RHA) has increasingly become the standard treatment for nonreconstructable radial head fractures, especially in young active patients where long-lasting function restoration is of paramount importance. However, long-term evidence of the results over time is still scarce. The purpose of this study was to document the long-term outcomes of RHA for acute radial head fractures. Thirty-eight patients (mean age, 41.9 years) treated with RHA with at least 10 years of follow-up were included in this study for clinical and radiographic evaluation: 14 patients had isolated radial head fractures and 24 had associated lesions (17 terrible triads, 6 transulnar fracture-dislocations, 1 Monteggia fracture). The clinical outcomes were quantified through the Mayo Elbow Performance Score (MEPS), the Broberg-Morrey score (B&M), and the 12-Item Short Form Health Survey questionnaire. All patients were evaluated for range of motion (ROM), strength, complications, revision surgeries, and postoperative satisfaction. Radiographic findings at the final follow-up were assessed through plain anteroposterior and lateral radiographs. At a mean follow-up of 14.5 years, the mean MEPS score was 96.4 (standard deviation [SD] 6.1). The mean B&M score was 93.0 (SD 7.7). The mean ROM in flexion-extension was 132° (SD 10.9) and 13° (SD 14.5), respectively, whereas the mean arc of motion in forearm rotation was 142° (pronation 76°, SD 21.0; supination 66°, SD 23.1). Three patients (7.9%) failed and underwent prosthesis explantation. The causes of prosthetic removal were 2 cases of elbow stiffness and 1 case of aseptic loosening. The presence of heterotopic ossifications was found in 9 patients (25.7%). Signs of moderate or severe elbow arthritis were observed in 14 patients (40%), 10 patients (28.6%) had radiographic evidence of stress shielding, and 16 patients (45%) presented various degrees of radiolucency areas around the stem. The press-fit implants showed higher rates of stress shielding compared with loose-fit implants (38.9% vs. 7.1%) and lower rates of radiolucency around the stem (28.6% vs. 71.4%). Survivorship rates for modular press-fit implants (Small Bone Innovation system) were 92.1% at 2 years, 5 years, and 14.5 years, whereas survivorship rates for modular loose-fit implants (Evolve; Wright Medical) were 100% at the final follow-up. After 15 years, elbows treated with RHA presented signs of arthritis in the majority of patients. However, patients with RHA implanted within 4 weeks for nonreconstructable fractures of the radial head sustained a limited number of failures and, despite a relatively high rate of post-traumatic arthritis, obtained a good long-term clinical outcome.
Medical subject headings
- Radius Fractures
- Elbow Joint
- Elbow Prosthesis
- Arthroplasty, Replacement, Elbow
- Joint Prosthesis
Anatomy
- elbow
- radius