Artificial Intelligence Versus Radiologist False-Positives on Digital Breast Tomosynthesis Examinations in a Population-Based Screening Program.

Shahrvini, Tara; Wood, Erika J; Joines, Melissa M; Nguyen, Hillary; Hoyt, Anne C; Chalfant, James S; Capiro, Nina M; Fischer, Cheryce P et al. · AJR Am J Roentgenol · 2026

retrospective_cohort · Level III

Where this comes from

Abstract

<b>BACKGROUND</b>. Insights into the nature of false-positive findings flagged by contemporary mammography artificial intelligence (AI) systems could inform the potential use of AI to reduce false-positive recall rates. <b>OBJECTIVE</b>. The purpose of this study was to compare AI and radiologists in terms of characteristics of false-positive digital breast tomosynthesis (DBT) examinations in a breast cancer screening population. <b>METHODS</b>. This retrospective study included 2977 women (mean age, 55 years) who were participating in an observational population-based screening study and underwent 3183 screening DBT examinations from January 2013 to June 2017. A commercial AI tool analyzed DBT examinations. Positive examinations were defined as having an elevated-risk result for AI and as having been assigned BI-RADS category 0 for interpreting radiologists. False-positive examinations were defined as the absence of a breast cancer diagnosis within 1 year. Radiologists rereviewed the imaging for AI-flagged false-positive findings. <b>RESULTS</b>. The false-positive rate was 10% for both AI (304/3183) and radiologists (308/3183). Of 541 total false-positive examinations, 233 (43%) were false-positives for AI only, 237 (44%) were false-positives for radiologists only, and 71 (13%) were false-positives for both. AI-only versus radiologist-only false-positives were associated with greater mean patient age (60 vs 52 years, <i>p</i> < .001), lower frequency of dense breasts (24% vs 57%, <i>p</i> < .001), and greater frequencies of a personal history of breast cancer (13% vs 2%, <i>p</i> < .001), prior breast imaging studies (95% vs 78%, <i>p</i> < .001), and prior breast surgical procedures (37% vs 11%, <i>p</i> < .001). The false-positive examinations included 932 AI-only flagged findings, 315 radiologist-only flagged findings, and 49 flagged findings concordant between AI and radiologists. AI-only flagged findings were most commonly benign calcifications (40%), asymmetries (13%), and benign postsurgical change (12%); radiologist-only flagged findings were most commonly masses (47%), asymmetries (19%), and indeterminate calcifications (15%). Of 18 concordant flagged findings that were biopsied, 44% yielded high-risk lesions. <b>CONCLUSION</b>. Imaging and patient-level differences were observed between AI and radiologist false-positive DBT examinations. Although only a small fraction of false-positive examinations overlapped between AI and radiologists, concordant flagged findings had a high rate of representing high-risk lesions. <b>CLINICAL IMPACT</b>. The findings may help guide strategies for using AI to improve DBT recall specificity. In particular, concordant findings may represent an enriched subset of actionable abnormalities.

Medical subject headings