ESR Essentials: diffusion-weighted MRI-practice recommendations by the European Society for Magnetic Resonance in Medicine and Biology.
expert_opinion · Level V
Where this comes from
- Record sourced from PubMed, PMID 41037070.
- Also identified by DOI 10.1007/s00330-025-12033-x and PMC identifier 12963196.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Diffusion-weighted imaging (DWI) offers critical insights into tissue microstructure through the assessment of water molecule random displacements and plays a central role in the assessment of neoplastic and non-neoplastic diseases. To successfully implement and use DWI in clinical practice, guidelines for acquisition, interpretation of image contrast and of artefacts should be followed, taking the disease process and body part into account. We recommend covering a b-value range of 0-1000 s/mm<sup>2</sup> in the brain (along at least six directions for white matter), and 50-800 s/mm<sup>2</sup> in the body. Available acquisition acceleration options should be used to reduce repetition time (TR), echo time (TE), and echo-planar imaging (EPI) distortions, while considering the penalty in signal-to-noise ratio (SNR) and image sharpness. DW images and the apparent diffusion coefficient (ADC) map should be read jointly for the clinical interpretation. Areas of slower diffusion are hyperintense on DW images and hypointense on the ADC map, and vice versa. Magnetic susceptibility distortions and signal drop-outs or pile-ups are particularly pronounced at air-tissue or metal-tissue interfaces and may obscure areas of interest or hinder the co-localisation with structural scans. By following these guidelines and recommendations, radiologists and imaging professionals can enhance diagnostic accuracy, reduce variability, and maximise the clinical value of DWI across diverse applications. KEY POINTS: This article provides an overview of DWI principles, clinical applications, potential pitfalls, and emerging advances, alongside expert recommendations for optimal implementation. We provide key considerations tailored to specific applications (neuro and whole-body imaging), including protocol optimisation, adherence to established guidelines, and quality assurance measures to minimise artefacts and ensure reproducibility. By following the guidelines and recommendations summarised in this work, radiologists and imaging professionals can enhance diagnostic accuracy, reduce variability, and maximise the clinical value of DWI across diverse applications.
Medical subject headings
- Diffusion Magnetic Resonance Imaging