Contemporary Analysis of Revision and Resection Rates in Radial Head Arthroplasty Used in Elbow Trauma.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 41182895.
- Also identified by DOI 10.1097/BOT.0000000000003120.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate revision and removal rates of radial head arthroplasty (RHA) for elbow trauma using modern press-fit modular implants. Retrospective cohort study. Urban academic medical center. Patients who underwent RHA (2012-2024) for isolated comminuted radial head fractures, combined head-neck fractures, terrible triad injuries, or Monteggia variants (OTA 2R1) were study eligible. Inclusion criteria consisted of treatment with press-fit modular implants and ≥1 year of clinical follow-up. Demographics, injury patterns, elbow range of motion, and postoperative complications-including fracture-related infection, nerve injury, periprosthetic fracture, implant resection, and non-resection procedures-were assessed. Implant survivorship was evaluated via Kaplan-Meier analysis. 250 patients were included (mean age 52.2 ± 17.8 years, range 18.1-88.3 years; mean length of follow up 43.8 ± 35.2 months, range 12.0-128.0 months, BMI 28.7 ± 6.3 kg/m2, 56.8% female). Common indications for RHA included Monteggia fractures (38.0%), isolated radial head fractures (23.6%), and terrible triad injuries (19.2%).Post-index surgery iatrogenic nerve injury occurred in 7.2%, most commonly involving the ulnar nerve. Fracture related infection occurred in 2.8% post index surgery, and one nonoperative periprosthetic fracture (0.4%) was observed.The resection rate was 7.2% (18/250), with 33.3% (6/18) of implant resection surgeries occurring within one year (mean length of follow up 43.8 ± 35.2 months, range 12.0-128.0 months). Common resection indications included postoperative stiffness (n=5), infection (n=4), and neuropathy (n=3). One-year implant survival was 97.6%, with mean survivorship of 8.5 ± 1.0 years (95% CI, 7.1-9.8).In total, 24 patients (9.6%) underwent additional non-resection procedures including nerve decompressions, elbow contracture releases with excision of heterotopic ossification, and manipulations under anesthesia.At final follow-up (mean 43.8 ± 35.2 months), mean range of motion was 125.4° flexion, -14.9° extension, 73.5° pronation, and 79.3° supination. No significant difference in length of follow-up was observed between patients with post-operative nerve injury (52.4 ± 38.2 months) and those without (42.5 ± 34.8 months, p = 0.16). With a 7.2% resection rate and one-year implant survival of 97.6%, contemporary press-fit modular RHA demonstrated durable elbow trauma outcomes.
Medical subject headings
- Reoperation
- Elbow Injuries
- Radius Fractures
- Elbow Joint
- Arthroplasty, Replacement, Elbow
Anatomy
- elbow
- radius