Is the Use of New Ceramic Heads with Titanium Sleeves on Retained Femoral Stems in Revision Total Hip Arthroplasty Associated with Femoral Head or Neck Junction Failure at Mean Eight-year Follow-up?
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 41318036.
- Also identified by DOI 10.1016/j.arth.2025.11.058.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Ceramic heads used in revision total hip arthroplasty (rTHA) typically utilize a titanium sleeve adapter to protect from damage by the retained femoral stem taper; however, there is sparse mid- to long-term data on this practice, and risk factors for failure remain relatively unknown. The purpose of this study was to determine revision-free survival, specifically for failure of the head and/or neck junction (HNJ) and all-cause re-revision in this patient population, and to identify factors associated with failure. We retrospectively identified all consecutive aseptic rTHA that used a new ceramic head with a titanium sleeve on a retained femoral stem at our institution between 2011 and 2022. A total of 316 rTHA (295 patients) were included with a mean follow-up of 7.7 years (range, 2.1 to 14.3). The mean age was 65 years, and 57% were women. The main indications for rTHA were adverse local tissue reaction (46%), instability (29%), and acetabular aseptic loosening (12%). Isolated modular component exchange was performed in 38% of revisions. Kaplan-Meier analysis was used to determine survivorship. We aimed to use multivariate logistic regressions to identify risk factors for HNJ failure and all-cause re-revision. There were no re-revisions for HNJ failure. The re-revision-free survival for HNJ failure was 100%. There were 66 hips (21%) that underwent re-revision at a mean time of 1.8 years, most commonly for instability (39 of 66), infection (17 of 66), and aseptic loosening (eight of 66). The 5- and 10-year all-cause re-revision-free survival was 81.1 and 77.0%, respectively. There were no implant or surgical factors associated with HNJ failure. Multivariate analyses identified not undergoing cup revision (P = 0.027) and rTHA for instability (P = 0.042) as risk factors for re-revision. New ceramic heads with titanium sleeves on retained femoral stems in rTHA are safe at a mean eight-year follow-up with no failures of the HNJ. Acetabular component retention and revision for instability were risk factors for all-cause re-revision.
Anatomy
- femur
- hip