Radiation Exposure during Elective Endovascular Abdominal Aortic Aneurysm Repair: A Nationwide Study of Patient Doses in Finland.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 41338376.
- Also identified by DOI 10.1016/j.ejvs.2025.11.058.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Endovascular aneurysm repair (EVAR) predisposes patients to significant radiation exposure, with well known harmful effects. This study aimed to assess the radiation doses and their consistency in Finland and to investigate the factors affecting the doses, to potentially allow future dose reductions. This retrospective, nationwide, multicentre study included all patients who underwent an elective standard EVAR procedure in Finland between 2017 - 2022. Data were collected from: body mass index (BMI); fluoroscopy time (FT); radiation exposure, including kerma area product (KAP) and cumulative air kerma at the patient reference entrance point (K<sub>a,r</sub>) from fluoroscopy and digital subtraction angiography (DSA); number of DSA series; and exposure parameters of the angiography systems. Descriptive statistics and linear regression analyses were performed to identify the parameters that significantly influenced radiation exposure. From all five centres that perform EVAR in Finland 1 185 EVAR procedures were included. Large variation in medians of total procedure KAP between the centres was observed, ranging 22.5 - 135.0 Gy·cm<sup>2</sup>. Median FT ranged 16.1 - 29.1 minutes. Both fluoroscopy and DSA showed large variation in radiation exposure. BMI did not significantly differ between the centres. The factors significantly affecting the dose in the multivariable linear regression model were BMI, FT, number of DSA acquisitions, DSA frame rate, and maximum copper filtration in fluoroscopy. Surprisingly high, up to six fold, between centre variability in total procedure radiation exposure was observed. The variability in the doses was mostly attributable to differences in exposure parameters (e.g., dose at detector level, copper filtration, and pulse rate); the manner in which radiation is used also played a significant role. In other words, both angiography system parameters and the working habits of the operator need to be optimised.
Medical subject headings
- Aortic Aneurysm, Abdominal
- Endovascular Aneurysm Repair
- Radiation Dosage
- Radiation Exposure