Patient-Specific Instrumentation Versus a Free-Hand Technique for Glenoid Baseplate and Peripheral Screw Placement in Reverse Total Shoulder Arthroplasty Using the Exactech Implant System: A Multicenter Randomized Controlled Trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 41407028.
- Also identified by DOI 10.1016/j.jse.2025.11.014.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Accurate positioning of the glenoid baseplate and peripheral screws is critical in reverse total shoulder arthroplasty (rTSA). Patient-specific instrumentation (PSI) has been introduced to improve surgical accuracy, but its benefits over conventional free-hand techniques remain uncertain. This study aimed to evaluate the accuracy of glenoid baseplate and peripheral screw placement between PSI-assisted and conventional free-hand rTSA. We conducted a prospective, multicenter, parallel-group, single-blinded, superiority randomized controlled trial across seven tertiary centers between March 2022 and December 2024. Patients aged ≥65 years undergoing primary rTSA were randomized 1:1 to PSI or free-hand group through a centralized web-based electronic case report form. No cross-over occurred, and all analyses were performed on an intention-to-treat basis. A standardized implant system (Exactech, Gainesville, FL, USA) was used in all cases. The primary outcome was the proportion of patients with postoperative CT-based deviation error from preoperative planning, including version (≥5°), inclination (≥5°), or position offset (≥2.5 mm) errors. The secondary outcomes included continuous deviation values and accuracy of peripheral screw placement (anteroposterior gap, superoinferior gap, and length gap deviations). Effect sizes with 95% confidence intervals (CI) were reported. Of 106 patients, 53 were included in the PSI and free-hand groups each. Baseline demographics and clinical characteristics were comparable between the groups. Baseplate positioning was similar between the groups, with version error 5 ± 5° vs. 5 ± 5°, inclination error 6 ± 5° vs. 5 ± 4° (mean difference +0.9°, 95% CI -0.8 to +2.6; p=0.309), and positional offset 3 ± 2 mm vs. 4 ± 2 mm (mean difference -0.3 mm, 95% CI -1.1 to +0.5; p=0.496). Conversely, PSI significantly improved peripheral screw placement accuracy, including anteroposterior gap (-1 ± 3° vs. 1 ± 6°; mean difference -1.9°, 95% CI -3.7 to -0.1; p=0.041), superoinferior gap (-2 ± 4° vs. 1 ± 6°; mean difference -2.7°, 95% CI -4.7 to -0.8; p=0.008), superior length gap (1 ± 6 mm vs. -2 ± 8 mm; mean difference +3.0 mm, 95% CI 0.2 to 5.8; p=0.039), and inferior anteroposterior gap (1 ± 6° vs. -3 ± 6°; mean difference +4.2°, 95% CI 2.0 to 6.4; p<0.001). Additionally, clinically relevant errors (>5°) were significantly less frequent in the PSI group for anterior (11.3% vs. 43.4%; p<0.001) and superior (20.8% vs. 41.5%; p=0.035) superoinferior gap. In primary rTSA, PSI did not improve glenoid baseplate positioning compared to the free-hand technique but significantly enhanced the accuracy of peripheral screw placement. Level II; Randomized Controlled Trial; Treatment Study.
Anatomy
- shoulder